Analog Output Rating
Voltage Outputs: 2.5 kOhm minimum load resistance
Current Outputs: 1 kOhm maximum load resistance at 24 V; maximum load resistance = [(Vcc - 4)/.02] Ohms
Output Protection
Protected against output short-circuit, continuous overload, transient overvoltages, and false pulse on power-up
Response Speed and Features
Description
Response
Speed
Repetition
Period
Repeatability
Cross-Talk
Avoidance
Energy Efficient
Light Resistance
Maximum
Range, Red3
Maximum
Range,
IR8504
Maximum
Range,
LIR14505
High Speed
500 µs
100 µs
100 µs
No
No
1200 mm
2400 mm
360 mm
Fast
1000 µs
100 µs
150 µs
Yes
No
1500 mm
3000 mm
450 mm
Standard
2 ms
100 µs
180 µs
Yes
Yes
1500 mm
3000 mm
450 mm
Long Range
8 ms
100 µs
180 µs
Yes
Yes
1950 mm
3900 mm
585 mm
Extra Long
Range
24 ms
100 µs
180 µs
Yes
Yes
3000 mm
6000 mm
900 mm
Operating Conditions
Temperature:
−
10 °C to +55 °C (+14 °F to +131 °F)
Storage Temperature:
−
20 °C to +85 °C (
−
4 °F to +185 °F)
Humidity: 50% at +50 °C maximum relative humidity (non-condensing)
Environmental Rating
IEC IP50, NEMA 1
Connections
PVC-jacketed 2 m or 9 m (6.5 ft or 30 ft) 5-wire integral cable; or integral 5-pin M8/Pico-style quick disconnect; or 150 mm (6 in) cable with a 5-pin
M8/Pico-style quick disconnect; or 150 mm (6 in) cable with a 5-pin M12/Euro-style quick disconnect
For Q3 or Q7 models, either a 5-pin M8/Pico-style or a 6-pin M8/Pico-style mating cordset may be used
Construction
Black ABS/polycarbonate alloy (UL94 V-0 rated) housing, clear polycarbonate cover
Required Overcurrent Protection
WARNING: Electrical connections must be made by qualified personnel in accordance with local and national electrical
codes and regulations.
Overcurrent protection is required to be provided by end product application per the supplied table.
Overcurrent protection may be provided with external fusing or via Current Limiting, Class 2 Power Supply.
Supply wiring leads < 24 AWG shall not be spliced.
For additional product support, go to
http://www.bannerengineering.com
.
Supply Wiring (AWG)
Required Overcurrent Protection (Amps)
20
5.0
22
3.0
24
2.0
26
1.0
28
0.8
30
0.5
Certifications
Industrial
Control
Equipment
3TJJ
Class 2 power
3 Excess gain = 1 (high sensitivity), opposed mode sensing. PIT46U plastic fiber used for visible LED models.
4 Excess gain = 1 (high sensitivity), opposed mode sensing. IT.83.3ST5M6 glass fiber used for IR models.
5 Excess gain = 1 (high sensitivity), opposed mode sensing. IT.83.3ST5M6 glass fiber used for IR models.