Sensor positions
threshold a programmable
% offset above the
presented condition
Threshold position
adjusted by
Manual Adjust
Darkest
(no signal)
Most Light
(saturated
signal)
Output OFF
Output ON
Condition
Presented
Figure 8. Dark SET (Light Operate shown)
Calibration SET
•
Sets a threshold exactly at the presented condition
•
Threshold can be adjusted using "+" and "-" rocker button (Manual Adjust)
A single sensing condition is presented, and the sensor positions a threshold exactly at the presented condition. When a
condition lighter than the threshold is sensed, the output either turns ON or OFF, depending on the LO/DO setting.
Sensor positions
threshold exactly at
the presented condition
Threshold position
adjusted by
Manual Adjust
Darkest
(no signal)
Most Light
(saturated
signal)
Output OFF
Output ON
Condition
Presented
Figure 9. Calibration SET (Light Operate shown)
Specifications
Sensing Beam
DF-G3: Visible red, 635 nm
DF-G3IR: Infrared, 850 nm
DF-G3LIR: Long infrared, 1450 nm
Supply Voltage
Voltage output models: 12 V to 30 V dc Class 2 (10% maximum ripple)
Current output models: 10 V to 30 V dc Class 2 (10% maximum ripple)
Power and Current Consumption (exclusive of load)
Standard display mode: 840 mW, Current consumption < 35 mA at 24 V dc
ECO display mode: 672 mW, Current consumption < 28 mA at 24 V dc
Supply Protection Circuitry
Protected against reverse polarity, overvoltage, and transient voltages
Delay at Power-Up
500 milliseconds maximum; outputs do not conduct during this time
Output Configuration
Voltage Output Models: 1 analog voltage output (user configurable as 1 V to 5 V or 0 V to 10 V) with 1 current sinking (NPN) or 1 current
sourcing (PNP) discrete output, depending on model.
Current Output Models: 1 analog current output (4 mA to 20 mA) with 1 current sinking (NPN) or 1 current sourcing (PNP) discrete output,
depending on model
Discrete Output Rating
100 mA maximum combined load—analog plus discrete outputs (derate 1 mA per °C above 30 °C)
OFF-state leakage current: < 5 µA at 30 V dc
ON-state saturation voltage: NPN: < 1.5 V; PNP: < 2 V
Analog Output Recovery Time
< 2 times the selected response speed
Analog Output Ripple Content (p-p)
< 0.5% of the full scale analog output
DF-G3 Long Range Expert
™
Dual Display Fiber Amplifier with Analog Output
P/N 190340 Rev. B
www.bannerengineering.com - Tel: +1-763-544-3164
11