Remove from a DIN rail
1. Push the DF-G3 up on the DIN rail (1).
2. Pivot the DF-G3 away from the DIN rail and remove
it (2).
Installing the Fibers
Follow these steps to install glass or plastic fibers.
1. Open the dust cover.
2. Move the fiber clamp forward to unlock it.
3. Insert the fiber(s) into the fiber port(s) until they
stop.
4. Move the fiber clamp backward to lock the fiber(s).
5. Close the dust cover.
Fiber Emitter
Port
Fiber Receiver
Fiber Clamp
Port
Move forward
to release the
fibers
NOTE: For optimum performance of DF-G3IR and DF-G3LIR models, glass fibers must be used.
Fiber Adapters
NOTE: If a thin fiber with less than 2.2 mm outer diameter is used, install the fiber adapter provided
with the fiber assembly to ensure a reliable fit in the fiber holder. Align the fibers to the end of the
adaptors. Banner includes the adapters with all fiber assemblies.
TO
FIBERS
TO
SENSOR
Fiber Outer Diameter (mm)
Adapter Color
Ø 1.0
Black
Ø 1.3
Red
Ø 2.2
No adapter needed
When connecting coaxial-type fiber assemblies to the amplifier, install the single-core (center) fiber to the Transmitter
port, and the multi-core (outer) fiber to the Receiver port. This will result in the most reliable detection.
TRANSMITTER
RECEIVER
Single-core fiber
Multi-core fiber
DF-G3 Long Range Expert
™
Dual Display Fiber Amplifier with Analog Output
P/N 190340 Rev. B
www.bannerengineering.com - Tel: +1-763-544-3164
3