![Bang & Olufsen BeoCenter 6-26 Скачать руководство пользователя страница 14](http://html1.mh-extra.com/html/bang-and-olufsen/beocenter-6-26/beocenter-6-26_service-manual_3736351014.webp)
2.6 Fault flow chart
Fault symtom
- Camcorder, no sound / and no picture
Possible cause
- Connection to camcorder
- PCB59, Camcorder defect
- Main chassis defect
If possible, check
camcorder on another
product
No picture
Sound OK
See next page
Check connection
between TV and the
camcorder
Connection OK?
Re-establish
connection
Select “CAMCORD”
on Beo4
Picture OK?
- - - - - - - -
Camcorder detector
defect
Check internal wire
connections W6 &
W2
Connections OK?
- - - - - - - -
Internal connections
Re-establish
connection
Replace
Main chassis
(module 999)
Fault may be located
in any of the PCBs
No
Yes
Replace
Main chassis
(module 999)
Replace Camcorder
(PCB59)
Camcorder defect
ABO-CENTER
v/HENRIKSENS