![Bang & Olufsen BeoCenter 6-26 Скачать руководство пользователя страница 12](http://html1.mh-extra.com/html/bang-and-olufsen/beocenter-6-26/beocenter-6-26_service-manual_3736351012.webp)
2.4 Fault flow chart
Fault symptom:
- No start up
- Standby light = blinking red/green
Possible causes:
- NTC defect
- Cable W09 to NTC defect
- Main chassis, module 999 defect
Check cable W09
between NTC module
and PCB4, SMPS
- - - - - - - -
Cable connection OK?
Replace cable W09
Product OK?
Replace NTC module
Product OK?
- - - - - - - -
NTC module
Replace Main chassis
(module 999)
No
Yes
ABO-CENTER
v/HENRIKSENS
ELEKTRONIK