Commissioning
74
Mobile Panel 7100 User's manual 1.51
Information about closing the attachment shaft
•
The gasket must be clean, undamaged and positioned correctly in the attachment shaft cover.
•
Pinched cables are not permitted.
•
The attachment shaft cover must be refastened with all previously removed screws (torque
for 5MP7120.034F-000 and 5MP7121.034F-000: 0.4 to 0.5 Nm, torque for 5MP7140.070N-000: 0.8
to 1.0 Nm, torque for 5MP7150.101E-000, 5MP7151.101E-000 and 5MP7151.101E-001: 0.5 to 0.7
Nm). Only then can the corresponding degree of protection be ensured again.