Technical data
Mobile Panel 7100 User's manual 1.51
19
The variant with 2 enable switches is only available on the MP715x. The 2 enabling switches are located on the
left and right sides of the Mobile Panel. This enabling device is equipped with internal evaluation electronics.
Both enabling devices allow for left- and right-handed operation. An enable switch consists of a three-position
operating element. Significant features include the dual-circuit design, direct opening action per EN 60947-1 and
direct opening action of the third switch position per EN 60947-5-8.
On a one- or two-button Mobile Panel 7151, the button can be read by the Control Center or a program using the
Automation Device Interface (ADI library) for testing purposes.
1
or
Enable switch
2 enable switches, with
one each in the left and right position
Enable switch
Enable switch
Figure 4: Enabling control device
Warning!
The enabling control device must be tested periodically (every 6 months) by actuating it to the panic
position. This test must be performed to determine whether the panic position is functional.