Appendix A
Mobile Panel 7100 User's manual 1.51
143
Appendix A
A.A Stop button
The following stop button is installed on Mobile Panel 7100 devices:
Information:
The following specified characteristic data, features and limit values are only valid for these individual
components and may differ from those of the complete system. The data specified for the complete
system applies to the complete system in which this individual component is used, for example.
SCHLEGEL BR FRVK stop button
Nominal voltage
1)
24 VDC, SELV
Current-carrying capacity
Max. 1000 mA (per contact)
Utilization category
DC-13 (per IEC 60947-5-1)
B10d value (switching cycles)
250,000
Variant
Dual-circuit, external wiring
Electrical isolation
500 VAC to rest for 1 minute
Figure 48: Stop button in revisions ≥ J0
1)
EN 60950 requirements must be observed.
A.B Enabling control device
Information:
The following specified characteristic data, features and limit values are only valid for these individual
components and may differ from those of the complete system. The data specified for the complete
system applies to the complete system in which this individual component is used, for example.
Information:
In order to ensure the specified safety characteristics, the enabling electronics must be taken out of
operation after 20 years at the latest.
Properties
Enabling control device
with one enable switch
Enabling control device
with two enable switches
Output type
Electromechanical switching contact
Solid-state output
Switchable nominal voltage (Ue)
24 VDC, SELV
1)
(voltage tolerance 19.2 VDC
to 30 VDC per EN 61131-2)
24 VDC, SELV
1)
(voltage tolerance 19.2 VDC
to 30 VDC per EN 61131-2)
Switchable nominal current (Ie)
500 mA (max.)
250 mA (max.)
Short circuit and overload protection
No
Yes
Reverse polarity protection
No
Yes
Utilization category
DC13
DC13
Operating cycles (B
10d
)
Switch position 2
1,000,000
1,000,000
Switch position 3
5,000,000
5,000,000
Actuating force
From switch position 1 to 2
Typically 3 N
Typically 3 N
From switch position 2 to 3
Typically 17 N
Typically 17 N
Electrical isolation
500 VAC to rest for 1 minute
500 VAC to rest for 1 minute
Output testing
-
Yes (test pulse duration ≤1 ms)
Changing grip function
-
Yes
Output synchronization
-
Yes
Specifications for EN ISO 13849-1:2015
Enable
Category
4
4
Performance level
e
e
Proof test interval
20 years
20 years
Specifications for EN 64508
SIL
-
3
PH
d
-
5.07 x 10
9
1/h
Specifications for EN 60947-5-1