Technical data
Panel PC 2200 built-in devices User's manual V 1.05 Translation of the original documentation
25
2.2.1.4 Mounting orientations
The following diagrams show the specified mounting orientations of Panel PC 2200 devices. A PPC2200 is only
permitted to be installed as shown or described below.
A
B
0°
C
D
0°
Figure 8: Panel PC 2200 - Mounting orientation
Mounting orientation
Ambient temperature limitation
1)
0°
0°
None
A
-1° to -90° (counterclockwise)
5°C
B
+1° to +90° (clockwise)
5°C
C, D
±180° (interfaces on top)
None
C
-1° to 90°
5°C
D
+1° to +90° (display facing down)
5°C
Table 16: Mounting orientations during operation
1)
The maximum ambient temperature must be reduced by ....
During installation, it is important to make sure that the spacing as described in section
is observed in order to achieve natural air circulation.