Technical data
24
Panel PC 2200 built-in devices User's manual V 1.05 Translation of the original documentation
2.2.1.3 Spacing for air circulation
To ensure sufficient air circulation, a specified clearance must be provided above, below, to the side and rear of
the unit. For the minimum specified clearance, see the following diagrams. This is valid for all variants.
Information:
The following figure and table exclusively show the thermal view of the complete system. If additional
space is required for operating or servicing the device, this must be taken into account during instal-
lation.
The air inlet and air outlet are shown in the following figure. Because the warm air rises from bottom to top, the
air inlet is at the bottom.
Air inlet
Air outlet
S4
Rear view
Side view
S3
S2
S3
S1
S1
S2
Figure 7: Panel PC 2200 - Spacing for air circulation
S1: ≥20 mm
S2: ≥50 mm
S3: ≥100 mm
S4: ≥50 mm
Caution!
The specified spacing for air circulation is based on worst-case operation at the maximum specified
ambient temperature. The maximum specified ambient temperature is not permitted to be exceeded!
If the specified spacing for air circulation cannot be maintained, the maximum specified temperatures
of the temperature sensors (see
"Temperature sensor positions" on page 33
) must be monitored by
the user and appropriate measures taken if these values are exceeded.