18 |
Connecting power |
Zeus Touch installation manual
Connecting power
Power connection (basic)
The Zeus Touch display can be powered by either 12
V or 24 V DC. Displays are protected against reverse
polarity, under voltage and over voltage.
The supplied power cable has a four core cable used
for:
•
power into the system (Red and Black wires)
•
controlling power state of the display or power state of
other displays and devices (Yellow wire)
•
connecting to an external alarm (Blue wire)
Connect red to (+) DC using a 5 amp fuse for Zeus
Touch12, and a 3 amp fuse for Zeus Touch7 and Zeus
Touch8. Connect Black to (-) DC. The display can be
powered on and off using the power button.
Power Control (yellow wire)
Planning is required how you want to be able to turn on and off the Zeus Touch an connected
compatible devices.
The yellow (Power Control) wire on the Zeus Touch power cable can either be an input that
will turn on the display when power is applied, or an output that turns on other devices when
the display is powered on. It can be confi gured at the installation stage to control the power
state of displays and compatible devices. When commissioning the system, displays can be
set to be a Power Control Slave or Power Control Master.
Power Control confi guration options of the Zeus Touch are:-
•
use the Power button to turn on the display only: Yellow wire not connected
•
display to turn on when power is applied to the display: Common red and yellow wires
•
use the Power button to turn on the display and other displays and or compatible devices
such as Broadband Radar: Yellow wire connected to a Power Control Bus. (Set one or more
displays to be a Power Control Master)
12 - 24 V DC
Red
Black
Yellow
+ _
Blue
(FUSE)
12 - 24 V DC
Red (FUSE)
Black
Yellow
Blue
+ _
No Power Control
Display will turn on and off when the
power button on the front of the unit is
pressed.
Leave yellow Power Control wire discon-
nected. Tape or heat-shrink end to prevent
shorting.
Auto Power on
Display will turn on when power is applied.
Common the yellow wire with the red wire
after the fuse.
Note: The unit can not be powered down by
power button, but can be put in to standby
mode. (screen backlight off ).
4
12 - 24 V DC
Red
Black
Yellow
+ _
Blue
(FUSE)