background image

4. Kit Contents

4

5

6

7

8

9

10

11

12

13

14

16

15

1

2

3

1.  

1 x SDO drive unit 

2.  

1 x Wall mount transmitter

3.  

2 x Transmitters

4.  

1 x Bent arm door attachment

5.  

1 x Straight arm door attachment 

6.  

1 x Wall bracket TS01

7.  

1 x Door bracket Locator

8.  

1 x Door bracket

9.  

3 x Pin Snap SSP 8 ZNU 31080

10. 

2 x Hex Head screw M8x25

11. 

1 x Pin 0890

12. 

2 x Clevis Pin 0829

13. 

2 x Hex Serration flange nut M8

14. 

4 x Hex flange screw ‘S’ M4 x 10

PLUS

15. 

2 x Track Bracket

16. 

1 x Pre-Assembled   

 

       track

10.00°

min

MINIMUM HEAD

ROOM FOR 

RAIL 57mm

DOORS 

HIGHES

T

POINT

15

1

16

5

4

6

7

12

8

14

11

9

13

10

5. Position

Perforated 

Angle

The Opener:

a. MUST BE installed in a dry position, protected from weather.

b. REQUIRES properly earthed 3 pin single phase power on the ceiling within an arms length of the opener.

c. Requires a MINIMUM HEADROOM of 57mm between the highest point of the door’s travel and the ceiling.

d. Use the diagram below as a reference when completing the installation.

12

9

9

5

Controll-A-Door

 

®

 - 

Installation instructions

Содержание Controll-A-Door Secure SDO-6

Страница 1: ...tions are intended for professional garage door installers All references are taken from inside looking out Controll A Door Doc 161052_02 Part 86297 Released 05 08 19 Smart SDO 7 Secure SDO 6 Sectional Door Openers ...

Страница 2: ...he Transmitter Code 12 15 2 Installation of the Wall Mounted Transmitter 12 15 5 Remotely Coding Transmitters 12 15 3 Erasing All Transmitter Codes 12 15 4 Vacation Mode 12 16 Smart Phone Control SDO 7 only 13 Installation Instructions 17 Home Owner Safety Warnings 14 18 Opener Safety Security 15 18 1 Your Door CAN NOT be used 15 18 2 Your Door CAN be used when 15 18 3 To Disengage the Opener 15 1...

Страница 3: ...n required to lift the door as per installation instructions Fall from ladder Ensure ladder is the correct type for job Ensure ladder is on flat firm ground that will take the weight without the legs sinking Ensure user has 3 points of contact while on ladder Crush injury from unsecured door Place a 2 metre exclusion zone around area under the door while it is unsecured Follow the installation ins...

Страница 4: ... a structural support You will need to locate the structural beams in the ceiling which are generally 400mm apart ii does it have exposed beams The opener is mounted to a perforated angle which must be securely fastened to a structural support like the exposed beams You may need to install a 40mm thick board not supplied between structural supports b Look at the wall above the garage door i Is it ...

Страница 5: ...x flange screw S M4 x 10 PLUS 15 2 x Track Bracket 16 1 x Pre Assembled track 10 00 min MINIMUM HEAD ROOM FOR RAIL 57mm DOORS HIGHEST POINT 15 1 16 5 4 6 7 12 8 14 11 9 13 10 5 Position Perforated Angle The Opener a MUST BE installed in a dry position protected from weather b REQUIRES properly earthed 3 pin single phase power on the ceiling within an arms length of the opener c Requires a MINIMUM ...

Страница 6: ...ural support can not be found contact a door profressional for installation DIY c Using step ladder and a level transfer this height to the wall above the door and mark a line 60mm above it across the centre line 7 2 Mounting the Wall Bracket a Draw two lines extending 21 5mm from each side of the centre point b Centre the wall bracket 6 over the intersection of these two lines Mark centres for at...

Страница 7: ... metal strips and 2 x shorter perforate L shape metal drop down strips Not supplied 9 Mounting Brackets and Arms 9 1 Mounting the Door Bracket a The door bracket locator 7 is placed over the door bracket 8 on the door s centre line one third down the top panel and mounted using M6 or equivalent screws not supplied b STEEL DOORS ONLY Bracket can be welded in place NOTE If in doubt about the door s ...

Страница 8: ...r must be well balanced and able to be operated by hand as per warranty conditions and AS NZS 4505 2012 18m2 236kg 18m2 236kg Minimum headroom 57mm 57mm Rated Operating Time 4 mins 4 mins Rated Temp 5 o C to 40 o C 5 o C to 40 o C Short Term Peak force 1100N 1100N Door travel speed mm sec 180mm 180mm Rated load 400N 400N Nominal force 200N 20kg 200N 20kg Receiver type Multi frequency UHF FM 433 47...

Страница 9: ... opener it will cycle through all three speed modes as shown in table iii Once at the desired speed release the CLOSE button iv To set the close limit inch the door by making single presses of the CLOSE button to the desired position We recommend the CLOSE limit position being the first point of contact of the rubber strip at the bottom of the door with the ground v If the door overshoots press th...

Страница 10: ...or stop when opening put the door into manual by pulling down on the manual release string to diesengage the motor and contact 13 62 63 for support 13 3 Test the Manual Door Operation Periodically disengage the opener and manually operate the door The door must be smooth to operate by hand The force required on the bottom rail should not exceed 20kg CAUTION Take care when completing a safety test ...

Страница 11: ... only when the safety beam is triggered ie car leaving the garage To enable the Auto Close function a Press the MODE button repetitively until the GEAR LED starts flashing b Press the OPEN button until the GEAR LED flashes i two 2 times to get to PE auto close or ii three 3 times to get to standard auto close c Press STOP SET button to enter parameter d The default setting forAuto Close is OFF Pre...

Страница 12: ...ore the transmitter code as per instructions above Test the transmitter button b Mount the transmitter in a convenient location yet out of reach of children and at least 1 5m off the ground c Make sure the door is visible from this location 15 5 Remotely Coding Transmitters Using this method transmitters can be coded without access to the opener s control panel as long as a pre coded transmitter i...

Страница 13: ...se must be installed as in accordance with AS NZS 60335 2 95 2012 This is in addition to regular professional servicing and monthly obstruction tests as detailed in Section 12 d Press and hold the OPEN button on the opener for 4 seconds The NETWORK LED will turn purple when Hot Spot is Active e Go to phone settings then WiFi and select B D000000 f Open App and tap on Start g Select setup a new Sma...

Страница 14: ...nal injury DO NOT attempt any garage door adjustment DO NOT use if repair or adjustment is needed Call for a professional garage door service CAUTION Emergency access If your garage has no pedestrian entrance door an emergency access device should be installed This accessory allows manual operation of the garage door from outside in case of power failure Entrapment under operating door Watch the m...

Страница 15: ...o move usually 2 seconds Make sure you can see the door when you use the transmitter b If you are in a vehicle you should aim the transmitter through your windscreen as shown c Check that the door is fully open or closed before you drive in or away d If you press the transmitter whilst the door is moving the door will stop The next press of the transmitter will move the door in the opposite direct...

Страница 16: ...ode 7 MODE STATUS LED Yellow Illuminates when in Diagnostics Mode 8 BATTERY STATUS LED Yellow SDO 7 only Illuminates when battery is charged and flashes when battery is charging in use or battery failed 9 REMOTE CONTROL STATUS LED Red Flashes on remote lockout and flickers on remote control activity 10 ADJUSTMENT LED Yellow Flashes a certain number of times depending on the parameter being changed...

Страница 17: ... recycling or collection all battery terminals must be securely insulated with a non conductive material to prevent any two batteries from short circuiting and generating heat during storage or transport Battery terminals may be insulated with electrical tape or batteries may be individually packaged in a non conductive material e g plastic bag or original packaging 21 3 Battery Disposal Battery T...

Страница 18: ...use the transmitter Check the battery status by pressing a button flashing or no light battery need changing Aim the transmitter through the windscreen The Courtesy light does not work LED has failed Change LED The door reverses for no apparent reason This may occur occasionally from environmental conditions such as areas that are windy dusty or have extreme temperature changes If Safety beams are...

Страница 19: ...5 Wireless LOCK is not unlocked and preventing door moving Check LOCK test by pressing emergency release button on the lock and then test door operation 6 Maintenance is due after pre set number of cycles Contact dealer to arrange service 7 Standby battery is faulty Contact 1300 769 850 within Australia for assistance 8 Door was obstructed Clear away any obstructions and test door opens closes cor...

Страница 20: ...ashing rapid flashing Battery not used not fitted Battery charged Battery charging when connected to power without power battery in use holding STOP for 10s will shutdown Battery failed REMOTE CONTROL STATUS LED 5 flashing rapid flashing Remote lockout Remote Control Activity NETWORK LED 6 SDO 7 Only 1 flash then pause 2 flashes then pause solid rapid flashing alternate flashing alternate solid Ho...

Страница 21: ...olding the STOP button for 10secs when running from battery backup will shut the PCB down so as to reduce battery current consumption to a minimum b Holding the STOP button for 4secs when a battery is fitted and running from mains power will cause the controller to test the battery state to determine if it is disconnected open circuit missing faulty or ready The Safety Obstruction Force is calcula...

Страница 22: ...n vi When the door is at the desired CLOSE position press the SET button 2 the GREEN LED on the OPEN button will now flash Button 1 inch Open Button 2 Set Button 4 inch Close OPEN limit i Using the programmed transmitter press and hold the button 1 to open To inch the door single presses of the button 1 will move the door to desired limit ii While inching to OPEN to set the open speed press and ho...

Страница 23: ...flashing b Press and hold STOP SET button for 2 seconds to check the door type until the main courtesy light turns solid ON or OFF Main courtesy light ON Tilt type J Type only Main courtesy light OFF Sectional type c Press and hold STOP SET for 6 seconds to change the door type until the main courtesy light turns solid ON or OFF If required repeat step b to check the door type selected d Press MOD...

Страница 24: ...s 1 year TRANSMITTERS ACCESSORIES 1 year b the door and opener are properly maintained by being serviced by a qualified professional at regular appropriate intervals What is appropriate may vary based on environmental factors eg weather salt exposure and level of usage Based on average use and environmental conditions B D recommends that the product is serviced by B D or a B D Representative withi...

Отзывы: