Default Settings & Speci
fi
cations
Factory default settings
Default
Step
Minimum
Maximum
Maximum opener run time
60 seconds
-
-
-
Courtesy light time
4 minutes (approx.)
-
-
-
Obstruction force margin
2
1
0
14
Auto-Close time
30 seconds
-
-
-
Technical speci
fi
cations
Power supply
230V - 240Va.c. 50Hz
Transformer rating
24Vd.c.
Standby power
2.2 Watts
Motor power
100 Watts
Motor type
24Vd.c. permanent magnet
Shuttle travel distance in the C-Rail
2.7m approx. (standard)
Maximum shuttle travel distance in the C-Rail
3.750 m (with one extension)
Maximum door opening:
Width:
Height:
Weight:
5500mm (16.5m
2
)
3000mm
100kg
Minimum headroom
30mm
Short term peak force
1000N (100kg) with Chain
800N (80kg) with Timing Belt
Lift force
600N (60kg) with Chain
500N (50kg) with Timing Belt
Nominal force
150N (15kg)
Receiver type
UHF Multi-frequency FM Receiver
Receiver code storage capacity
14 X 4 button Transmitter Codes
Transmitter frequency
UHF Multi-frequency FM Transmitter
Coding type
Code Hopping
Number of code combinations
Over 4.29 billion random codes
Code generation
Non-linear encryption algorithm
Transmitter battery
CR2032 (3 Volts)
Courtesy light
LED (Light Emitting Diodes)
Controller fuse
10A slow blow
*The actual travel of the door depends on con
fi
guration of the connecting arms.
Note: Intermittent operations may occur in areas which experience very strong winds. The strong wind puts extra pressure