Figure 1
GUARDING AND INTERLOCKS
Safeguards:
•
Main Tool Housing: Covers primary mechanical body and actuators to prevent pinching during operation
•
Head cover: Covers the mechanical head piece of the tool to prevent pinching during cutoff process
•
Circuit breaker: Housed inside main enclosure.
•
Power cord: Main method of removing power to unit. Unplug from wall or main enclosure.
Interlocking functions and features:
•
The tool is not intended to operate without guards in place. The tool does not have any interlock
functions or features that prevent operation if the guards are missing or enclosures are open. It
is the responsibility of the user to provide safety interlocks if required.
Securing machine for safe maintenance:
•
The tool must have all power and compressed air sources removed before service.
•
All guards must be replaced, and enclosures closed before power and air sources are
reconnected to the unit.
•
Before preventive maintenance, disconnect device from wall. The appliance plug is the
disconnect device.
•
The Device comes with an emergency stop (E-Stop button)