FACTORY PROGRAM SETTINGS
See page 35-38 for additional information about these settings
Table 5
Tab
Setting
Value
General
Target Torque
40%*
Setpoints
Min Supply Pressure
75 PSI
Max Supply Pressure
85 PSI
Torque Tolerance
0.10 in-lbf
Min Punch Duration
0.5 ms
Max Punch Duration
5.0 ms
Min Punch Pressure
63 PSI
Max Punch Pressure
67 PSI
Timing
Line Up Tool Timeout
10 s
Position Sensors Debounce
0.01 s
Cut Off Delay
0.05 s
Punch Extend Duration
0.10 s
Auto Eject Duration
0.5 s
Cut Retract Delay
0.20 s
Speed
Max Tension Speed
50%
*Recommended target torque is 40% for optimal component life and performance. For additional clamping