36
User Manual
IT8000
3/8” Tie
-Lok® Data Tool
Document #P80080 Rev. B
© Copyright
BAND-IT-IDEX, Inc. 2022
All rights reserved
All rights reserved
BAND-IT-IDEX, Inc.
A Unit of IDEX Corporation
4799 Dahlia Street
Denver, CO 80216-3070 USA
P: 1-800-525-0758
Figure 61
Figure 62
Settings Screen
–
Error
Error bypass
–
Automatically resets errors
without hitting
Reset Error
Enable Error Codes Passcode
–
Requires a
passcode to clear an error
Error Codes to Require Passcode
–
Number
of errors in a row before the passcode is
needed.
Settings Screen
–
Setpoints
Min/Max Supply Pressure
–
Prevents tool
from operating outside the settable supply
pressure range
Min/Max Punch Pressure
–
Prevents tool
from operating outside the settable punch
pressure range
Min/Max Punch Duration
–
Settable range of
punch duration. Tool will give error outside
of range.
Torque Tolerance
–
Tool will give error if
cycle torque is outside of target torque.
Cycle Warning Count
–
PM count to notify
when the tool needs to be regreased