TIE INSPECTION
CLAMP PLACEMENT
ss
Buckle location is critical to clamp performance. Use the following guidelines as a reference.
•
Do not install clamps at an angle (Fig. 28)
•
Buckle locations cannot be over air gaps (Fig. 30)
•
Avoid sharp corners, add largest radius possible on square corners (Fig. 29)
•
Tie-Lok® can be installed on flat surfaces
•
Do not install clamps on tapered surfaces or on tube bends (Fig.29)
•
Tie-Lok®
advised min installed diameter is 1”
•
The buckle area of the shield must be free of voids and wrinkles
For specific questions contact your BAND-IT-IDEX account manager.
Locking Dimple
The IT8000 forms a locking dimple into the Tie-Lok®
Tie with the punch and cuts the remaining tail.
When installing a Tie-Lok® tie, a visual check is
recommended to verify the presence of a locking
dimple after the tie has been applied.