MOL81 485 1312/MOL81 485 1337
MOL81 485 1312-MOL81 485 1337-UM-1.4-EN
12/20
Command:
01 CF 00 42 00 03 C1 C2
Reply:
01 CF 06 00 ST CH CL CV CI C1 C2
where CF = 3 or 4
ST = status byte (for details see §6.6).
CH = tag code, high-order byte.
CL = tag code, low-order byte.
CV = counter for valid tag sightings.
CI = counter for invalid tag sightings.
CV and CI counters are reset when:
-
A new code is read twice (i.e. on VA and NC status bits rising edge).
-
The same tag disappears and appears again.
Examples:
Command:
01 03 00 42 00 03 A5 DF
Reply:
01 03 06 00 8D 33 34 20 30 C1 C2 (new valid code = 0x3334)
Command:
01 04 00 42 00 03 10 1F
Reply:
01 04 06 42 81 00 00 00 00 C1 C2
(no code available)
6.4 Command: 125 KHz emitter control
This command will activate or deactivate the 125 kHz emitter. The command can be sent at any time..
Command:
01 10 00 43 00 01 01 EM 00 C1 C2
Reply:
01 10 00 43 00 01 F0 1D
where EM contains one useful bit:
D7
D0
0 0 0 0
0 0
0 VE
VE :
Activate emission ( 0 = activate, 1 = deactivate )
Example:
Command:
01 10 00 43 00 01 01 01 00 59 33
(deactivate emission)
Reply:
01 10 00 43 00 01 F0 1D
Command:
01 10 00 43 00 01 01 00 00 58 A3
(activate emission)
Reply:
01 10 00 43 00 01 F0 1D
6.5 Command: Read Firmware Version
This command reads the firmware version.
The reply contains one word version (2 bytes, high-order byte first).
D15
D12 D11
D8
D7
D4 D3
D0
type
version
major revision
minor revision
where type identifies the equipment. Only one value is currently defined:
11 (0xBH) – MOL1312
The other 3 nibbles define the version number coded in BCD, e.g. 012H corresponds to 0.1.2