OPERATOR
’S MANUAL
with Maintenance Information
Maintenance
59
a
b
c
a up limited switch
b down limited switch
c slope sensor
6 Tag and disconnect the wires of the up
limit switch wire harness.
7 Securely connect together the terminals of
the two wires of the up limit switch.
8 Turn the key switch to ground control and
turn the red Emergency Stop button
clockwise to the on position at both the
ground and platform controls.
9 Raise the platform to release the safe arm.
10 Put the safe arm to home position.
11 Fully raise the platform. Release the toggle
switch.
⊙
Result: The alarm should sound.
¤
Result: The alarm does not sound.
Calibrate the platform overload system.
12 Using the manual lowering knob, lower the
platform to the stowed position.
13 Securely connect the wires of the up limit
switch.
14 Fully raise the platform. Release the toggle
switch.
⊙
Result: The alarm should not sound. The
system is functioning correctly.
¤
Result: The alarm sounds. The system is
not functioning correctly. Troubleshoot the
limit switch, limit switch wire harness or
limit switch mount bracket or the platform
overload system needs to be calibrated.
15 Lower the platform approximately 8.2 ft /
2.5 m from the ground.
16 Lift the safety arm, move it to the center of
the scissor arm and rotate the safety arm
away from the machine and let it hang
down.
17 Lower the platform onto the safety arm.
Crushing hazard. Keep hands
clear of the safety arm when lowering the
platform.
18 Install the up limited switch cover.
19 Install the limited switch house cover.
20 Raise the platform to release the safe arm.
21 Put the safe arm to home position.
22 Lower the platform to the stowed position.
Содержание SM0114113
Страница 3: ......
Страница 5: ......
Страница 17: ...OPERATOR S MANUAL with Maintenance Information Decals 12...