OPERATOR
’S MANUAL
with Maintenance Information
Function Tests
21
1 Select a test area that is firm, level and
free of obstruction.
2 Be sure the battery pack is connected.
At the Ground Controls
3 Turn the red Emergency Stop button
clockwise to the on position at both the
ground and platform controls.
4 Turn the key switch to ground control.
5 Observe the diagnostic LED readout on
the ECU window.
⊙
Result: The LED
should look like the
picture at right.
Test Emergency Stop
6 Push in the ground red Emergency Stop
button to the off position.
⊙
Result: No functions should operate.
7 Turn the red Emergency Stop button
clockwise to the on position.
Test Up/Down Functions
A buzzer with different sound frequency is
controlled in central system. The descent
alarm sounds at 60 beeps per minute. The
alarm that goes off when the pothole guards
have not deployed sounds at 150 beeps per
minute. The alarm that goes off when the
machine is not level sounds at 150 beeps per
minute. An optional automotive-style horn is
also available.
8 Turn the key switch to off or platform
position.
9 Move up and hold the platform up / down
switch.
⊙
Result: No function should operate.
10 Turn the key switch to ground control
position.
11 Move up and hold the platform up / down
switch.
⊙
Result: The platform should rise.
12 Move down and hold the platform up /
down switch.
⊙
Result: The platform should lower to end.
The descent alarm should sound while the
platform is lowering.
Test the Emergency Lowering
13 Activate the up function and raise the
platform approximately 2 ft / 60 cm.
14 Pull the emergency lowering knob.
⊙
Result: The platform should lower. The
descent alarm will not sound.
15 Turn the key switch to platform control.
At the Platform Controls
Test Emergency Stop
16 Push in the platform red Emergency Stop
button to the off position.
⊙
Result: No functions should operate.
17 Turn the red Emergency Stop button
clockwise to the on position.
⊙
Result: The LED indicator light should
come on.
Test the Horn
18 Push the horn button.
⊙
Result: The horn should sound.
Test Function Enable and Up/Down
Functions
19 Do not hold the function enable switch on
the control handle.
20 Slowly move the control handle in the
direction indicated by the blue arrow, then
Содержание SM0114113