OPERATOR
’S MANUAL
with Maintenance Information
Operating Instructions
32
Display Description
76
Motor Controller Left Drive Motor Fault: Check connections to the motors. Cycle power
to the lift and if that does not resolve the issue, replace the Motor Controller.
77
Motor Controller Right Drive Motor Fault: Check connections to the motors. Cycle
power to the lift and if that does not resolve the issue, replace the Motor Controller.
78
Pump Motor Short Fault: Check connections to the pump motor. Cycle power to the lift
and if that does not resolve the issue, replace the Motor Controller.
79
Left Drive Motor Short Fault: Check the Motor connections and make sure they are
tight. Check the Motor for a short.
80
Over 80% Load Warning: Platform is getting close to its limit of weight. Consider not
adding more load.
81
Right Drive Motor Short Fault: Check the Motor connections and make sure they are
tight. Check the Motor for a short.
82
Right Brake Coil Fault: Check the connections to the Coil’s terminals and make sure
they are tight. If so, check the coil itself to see if it is open or shorted.
83
Left Brake Coil Fault: Check the connections to the Coil’s terminals and make sure they
are tight. If so, check the coil itself to see if it is open or shorted.
90
Over 90% Load Warning: Platform is getting close to its limit of weight. Consider not
adding more load.
99
Over 99% Load Warning: Platform has reached its limit of weight. Do not add more
load.
For more information, please consult the appropriate Ballymore Service Dept.