14
english
5
Configuration and parameterization (continued)
Processing time (
Minimum Cycle Time
)
The
Minimum Cycle Time
must be greater than the internal
processing time. The processing time depends on the
length of the BTL7-V50D-…, the parameterized number
of magnets and the selected
I/O Assembly
. It is shorter the
fewer magnets are parameterized and the less data is
collected in the
I/O Assembly
.
The following table lists the minimum processing times:
The
number of
magnets
I/O Assembly
Nominal length/mm
25…
250
251…
600
601…
1300
1301…
2700
2701…
5500
5501…
7600
7601…
7800
1
Position Value
860 μs
990 μs
1240 μs
2020 μs
4020 μs
5520 μs
5720 μs
1
Position Time 1
1010 μs
1140 μs
1390 μs
2020 μs
4020 μs
5520 μs
5720 μs
1
Position Velocity 1
910 μs
1040 μs
1290 μs
2020 μs
4020 μs
5520 μs
5720 μs
1
Position Velocity Time 1
1060 μs
1190 μs
1440 μs
2020 μs
4020 μs
5520 μs
5720 μs
2
Position 1 and 2
930 μs
1040 μs
1530 μs
3030 μs
6030 μs
8280 μs
8580 μs
2
Position Velocity 1 and 2
1030 μs
1160 μs
1530 μs
3030 μs
6030 μs
8280 μs
8580 μs
3…4
Position Time 1 to 4
1220 μs
1300 μs
1530 μs
3030 μs
6030 μs
8280 μs
8580 μs
3…4
Position Velocity Time 1 to 4
1320 μs
1550 μs
1800 μs
3030 μs
6030 μs
8280 μs
8580 μs
5…8
Position Time 1 to 8
1500 μs
1630 μs
1880 μs
3030 μs
6030 μs
8280 μs
8580 μs
5…8
Position Velocity Time 1 to 8
1900 μs
2030 μs
2280 μs
3030 μs
6030 μs
8280 μs
8580 μs
9…16
Position 1 to 16
1910 μs
2040 μs
2290 μs
3030 μs
6030 μs
8280 μs
8580 μs
9…16
Position Time 1 to 16
2060 μs
2190 μs
2440 μs
3030 μs
6030 μs
8280 μs
8580 μs
9…16
Position Velocity 1 to 16
2710 μs
2840 μs
3090 μs
3590 μs
6030 μs
8280 μs
8580 μs
9…16
Position, Velocity Time 1 to 16
2860 μs
2990 μs
3240 μs
3740 μs
6030 μs
8280 μs
8580 μs
Tab. 5-3: Minimum processing times