www.balluff.com
BTS M30E0-_ _ _-H0001-S04G
Infrared Temperature Sensor
37
15
IO-Link Interface
english
15.5 System Commands
Index
(dec)
Name
Data
Format Access
Value Range (dec)
Remarks
0x0002 (2)
System
Command
UINT8
W
0x01 (1) = ParamUp-
loadStart
Block parameterizing
Start Blockparameter Upload
0x02 (2) = ParamUp-
loadEnd
Stop Blockparameter Upload
0x03 (3) = Param-
DownloadStart
Start Blockparameter Download
0x04 (4) = Param-
DownloadEnd
Stop Blockparameter Download
0x05 (5) = Param-
DownloadStore
Stop Blockparameter Download and
Upload Request
0x06 (6) = ParamBreak
Abort block parameterizing
0x40 (64) = Teach
Apply
Teach
Channel
Save and apply switch points
0x43 (67) = SP1 Two
Value Teach TP1
Teach TP1 of SP1
0x44 (68) = SP1 Two
Value Teach TP2
Teach TP2 of SP1
0x45 (69) = SP2 Two
Value Teach TP1
Teach TP1 of SP2
0x46 (70) = SP2 Two
Value Teach TP2
Teach TP2 of SP2
0x4F (79) = Teach
Cancel
Cancel teach-in
0x4B (75) = Teach
Emissivity
Teach emissivity (True Temperature
must first be set)
0xA2 (162) = BDC
Reset
Reset
Reset BDC addressed by Teach-In
Channel to factory default
0xA5 (165) = Reset
Operating Hours
(Individual)
Reset individual operating hours
counter to 0
0x80 (128) = Device
Reset
Reset device
0x82 (130) = Restore
Factory Settings
Reset the sensor configuration to
the default factory settings
Содержание BTS M30E0-PSB-H0001-S04G
Страница 1: ...deutsch Betriebsanleitung english User s Guide BTS M30E0 UUI H0001 S04G BTS M30E0 PSB H0001 S04G ...
Страница 2: ...www balluff com ...
Страница 3: ...BTS M30E0 UUI H0001 S04G BTS M30E0 PSB H0001 S04G Betriebsanleitung deutsch ...
Страница 49: ...BTS M30E0 UUI H0001 S04G BTS M30E0 PSB H0001 S04G User s Guide english ...
Страница 95: ......