BTS M30E0-_ _ _-H0001-S04G
Infrared Temperature Sensor
14
5
Operating Element and Display (Local User Interface)
english
5.6
Rotating the Screen Display
The IR temperature sensor has an internal orientation sensor. Depending on the orientation of the sensor when
installed the display content is automatically rotated and thus adjusts to the viewer. The orientation sensor is enabled
by default. If desired the orientation sensor can be disabled from the menu. The display orientation can also be set
from the menu (see 11.4 Display Settings on page 27).
5.7
Timeouts
5.7.1
Timeout Display
The display contrast is automatically reduced 2 min after the last time a button was pressed. After 10 min without
pressing a button the display is turned off. Pressing any button turns the display on again. If key lock is enabled, the
contrast is reduced after 2 s without pressing a button, and the display is turned off after 10 s. In alignment mode the
display is turned off after 30 min and teach-in after 10 min.
5.7.2
Timeout Menu
The menu for parameterizing the sensor is automatically exited 1 min after the last time a button is pressed. After
enabling key lock, in alignment mode or teach-in turning off the display automatically returns from the menu.
5.7.3
Overview
Menu is terminated
Display contrast is
reduced
Display is turned off
Normal
1 min
2 min
10 min
Aligning the sensor
30 min
–
30 min
Teach-in
10 min
–
10 min
Key lock active
10 s
2 s
10 s
5.8
Indicator LEDs
Display element
Function
LED OUT1 (yellow)
Temperature threshold digital output 1
– LED on
Upper switching threshold exceeded
– LED off
Lower threshold exceeded
– LED flashes
Error (see section 14 Error Handing and Display on page 30)
LED OUT2 (yellow)
Temperature threshold digital output 2
– LED on
Upper switching threshold exceeded
– LED off
Lower threshold exceeded
– LED flashes
Error (see section14 Error Handing and Display on page 30)
LED ON (green)
Power indicator
– LED lights up
Sensor ready
– LED off
Sensor not ready
– LED flashes (ratio t
on
/t
off
=9:1)
IO-Link communication
– LED flashes (ratio 1:1)
Error (see section14 Error Handing and Display on page 30)
5.9
Local User Interface & IO-Link Interface
All parameters which can be set using the buttons can also be set via the IO-Link interface if present. A teach-in can
be performed at the same time only using one of the two interfaces.
Содержание BTS M30E0-PSB-H0001-S04G
Страница 1: ...deutsch Betriebsanleitung english User s Guide BTS M30E0 UUI H0001 S04G BTS M30E0 PSB H0001 S04G ...
Страница 2: ...www balluff com ...
Страница 3: ...BTS M30E0 UUI H0001 S04G BTS M30E0 PSB H0001 S04G Betriebsanleitung deutsch ...
Страница 49: ...BTS M30E0 UUI H0001 S04G BTS M30E0 PSB H0001 S04G User s Guide english ...
Страница 95: ......