![Balluff BTS M30E0-PSB-H0001-S04G Скачать руководство пользователя страница 73](http://html1.mh-extra.com/html/balluff/bts-m30e0-psb-h0001-s04g/bts-m30e0-psb-h0001-s04g_user-manual_469851073.webp)
www.balluff.com
BTS M30E0-_ _ _-H0001-S04G
Infrared Temperature Sensor
25
11
Configuring the IR Temperature Sensor
english
11.2.2 Peak Value Detection
The target objects may show locally differing temperatures. Due to the distance-dependent field of view of the sensor,
moving objects would result in fluctuations in the output signal. Peak value detection can be used to hold a local
maximum of the output signal for a settable number of successive measurements.
Example: When there is scaling on steel peak detection makes it possible to display the temperature of the steel while
suppressing scaled and therefore cooler locations.
Setting peak value detection
OUT
[°C]
t
1
Output signal without peak value detection
2
Output signal with peak value detection = 10 (peak value is held for
max. 10 additional measurements)
1.
Turn on peak value detection with [
▲
] or turn it off with [
▼
]. Use [
↵
].
2.
Set number of measurements for holding the peak value and confirm
with [
↵
].