BTL5-S1_ _-M_ _ _ _-P-S32/S147/KA_ _
Micropulse Linear Transducer in Profile Housing
9
english
8
Technical Data
The following are typical values at DC 24 V and room temperature. Fully operational after power-up, with full accu-
racy after warm-up. Values are with BTL5-P-3800-2, BTL5-P-4500-1 or BTL5-P-5500-2 magnet held at a constant
offset from the transducer or with captive magnet BTL5-F/M/N-2814-1S (see magnet section for exceptions):
Resolution (LSB)
depending on version:
BTL5-S1_
1
...
1 µm
BTL5-S1_
2
...
5 µm
BTL5-S1_
3
...
10 µm
BTL5-S1_
4
...
20 µm
BTL5-S1_
5
...
40 µm
BTL5-S1_
6
...
100 µm
BTL5-S1_
7
...
2 µm
BTL5-S1_
8
...
50 µm
Non-linearity
for resolution < 10 µm
± 30 µm
for resolution > 10 µm
± 2 LSB
Output data
Update rate f
max
< 2 kHz
Hysteresis
< 1 LSB
Repeatability
< 2 LSB
(reso hysteresis)
Temperature coefficient
(6 µm + 5 ppm * nominal length)/K
Shock loading
100 g/6 ms
per IEC 60068-2-27
1
Continuous shock
100 g/2 ms
per IEC 60068-2-29
1
Vibration 12 g, 10 to 2000 Hz
per IEC 60068-2-6
1
1
Individual specifications as per
Balluff factory standard
8.1
Dimensions, weights,
ambient conditions
Nominal length
< 4000 mm
Dimensions
➥
➥
➥
➥
➥
page 4
Weight
approx. 1.4 kg/m
Housing
anodized
aluminum
Housing attachment
Mounting clamps with isolation
bushings and screws
Operating temp. –40 °C to +85 °C
Humidity < 90%, non-condensing
Protection class per IEC 60529
IP 67 when closed up
8.2
Supply voltage
(external)
Regulated supply voltage
BTL5-S1...
DC 20 to 28 V
Ripple
< 0.5 V
pp
Current draw
< 90 mA
Inrush
< 3 A/0.5 ms
Polarity reversal protection built-in
Overvoltage protection
Transzorb diodes
Electric strength
GND to housing 500 V
Cable length
Clock frequency
< 25 m
< 1000 kHz
< 50 m
< 500 kHz
< 100 m
< 400 kHz
< 200 m
< 200 kHz
< 400 m
< 100 kHz
Table 8-1: Clock frequency
Emission tests:
RF Emission
EN 55011
Group 1, Class A+B
Noise immunity tests:
Static electricity (ESD)
EN 61000-4-2
Severity level 3
Electromagnetic fields (RFI)
EN 61000-4-3
Severity level 3
Fast transients (Burst)
EN 61000-4-4
Severity level 3
Surge
EN 61000-4-5
Severity level 2
Line-induced noise induced by
high-frequency fields
EN 61000-4-6
Severity level 3
Magnetic fields
EN 61000-4-8
Severity level 4
The CE Mark verifies
that our products meet
the requirements of
EC Directive
89/336/EEC (EMC Directive)
and the EMC Law. Testing in our
EMC Laboratory, which is accred-
ited by DATech for Testing Electro-
magnetic Compatibility, has con-
firmed that Balluff products meet
the EMC requirements of the fol-
lowing Generic Standards:
EN 61000-6-4 (emission)
EN 61000-6-2 (noise immunity)
UL authorization
File No.
E227256
8.3
Control signals
IInterface
RS 485/422
Clock input
+Clk, –Clk
(via optical coupler)
Clock frequency max. 1000 kHz
Output data
24 or 25 bit serial
Position inforData, –Data
8.4
Connection to processor
+Clk, –Clk, +Data, –Data, 24 V,
GND
Cable, twisted-pair, shielded
max. length 400 m, Ø 6 to 8 mm
The clock frequency t is a function
of the cable length:
No. 846 081 - 726 E • 00.000000 • Edition 0510; specifications subject to changes.