BTL5-S1_ _-M_ _ _ _-P-S32/S147/KA_ _
Micropulse Linear Transducer in Profile Housing
7
english
5
Startup
5.1
Check connections
Although the connections are polar-
ity reversal protected, components
can be damaged by improper con-
nections and overvoltage. Before
you apply power, check the connec-
tions carefully.
5.2
Turning on the system
Note that the system may execute
uncontrolled movements when first
turned on or when the transducer is
part of a closed-loop system whose
parameters have not yet been set.
Therefore make sure that no haz-
ards could result from these situa-
tions.
5.3
Check output values
After replacing or repairing a trans-
ducer, it is advisable to verify the
values for the start and end position
of the magnet in manual mode. If
values other * than those present
before the replacement or repair are
found, a correction should be made.
* Transducers are subject to modifi-
cation or manufacturing tolerances.
5.4
Check functionality
The functionality of the transducer
system and all its associated com-
ponents should be regularly
checked and recorded.
5.5
Fault conditions
When there is evidence that the
transducer system is not operating
properly, it should be taken out of
service and guarded against unau-
thorized use.
5.6
Noise elimination
Any difference in potential - current
flow - through the cable shield
should be avoided. Therefore:
–
Use the isolation bushings, and
–
Make sure the control cabinet
and the system in which the
BTL5 is contained are at the
same ground potential.
6
Versions (indicated on part label)
Supply voltage: 1 = DC 24 V
Electr. connection, S32:
with connector, 8 pin
BTL5-S102-M0450-P-S32
S147: with connector, 7 pin
KA05: with 5 m cable
Profile form factor
Nom. length (4digits):
M = metric in mm
Resolution: 1 = 1 µm
2 = 5 µm
3 = 10 µm
4 = 20 µm
5 = 40 µm
6 = 100 µm
7 = 2 µm
8 = 50 µm
Code: 24 bit 0 = binary, rising
1 = Gray, rising
2 = binary, falling
3 = Gray, falling
25 bit 6 = binary, rising
7 = Gray, rising
8 = binary, falling
9 = Gray, falling
Micr
opulse
Linear T
ransducer
SSI interface
6.1
Included in shipment
Transducer with condensed guide
Mounting brackets
6.2
Available lengths
To ensure flexible application,
nominal transducer lengths of from
50 to 4000 mm with following in-
crements are available:
Stroke lengths
[mm]
Increments
[mm]
50 ... 1000
50
1000 ... 2000
100
2000 ... 4000
250
Other stroke lengths on request.