6.14 Humidity
6.14.1 Description
The function monitors the air humidity in the device and
informs of changes through corresponding IO-Link events.
The humidity detection returns an immediate reaction in
the event of a critical failure. This reaction is triggered if the
humidity rises above a fixed threshold value and gives the
clear if a satisfactory humidity value is again achieved. The
status when the level is exceeded the first time is stored
permanently.
6.14.2 Process Data
Object ID
Name
Description
Direction
0x0023 (35)
Humidity Bad
Output of the current humidity evaluation; FALSE means a
humidity below the threshold value, TRUE means a humidity value
equal to or above the threshold value.
Input
Tab. 6-66: Humidity detection – Process data
6.14.3 ISDU
Name
Index
Subindex Access
Length
Data
Type
Data Storage
Default
Humidity
0x005C
(92)
0
R
9 bytes
n/a
Humidity Bad
1
R
1 byte
BOOL
n/a
–
Operating Hours At Exceedance
2
R
4 bytes
UINT32
n/a
–
Temperature at Exceedance
3
R
4 bytes
INT32
n/a
–
Tab. 6-67: Humidity detection – ISDU
Humidity Bad
The status of the humidity is displayed as a Boolean value.
If the value is TRUE, the signal quality is above the
threshold value; if the value is FALSE, the signal quality is
below the threshold value. The evaluation includes a
hysteresis for better signal stability.
Operating Hours At Exceedance
The operating hours value at the first exceedance of the
threshold value is stored.
Temperature At Exceedance
The temperature value at the first exceedance of the
threshold value is stored.
6
Secondary Device Functions (continued)
BOS R254K-UUI-RH10-S4
Photoelectric Sensors
Содержание BOS R254K-UUI-RH10-S4
Страница 1: ...deutsch Konfigurationsanleitung english Configuration Guide BOS R254K UUI RH10 S4...
Страница 2: ...www balluff com...
Страница 3: ...BOS R254K UUI RH10 S4 Konfigurationsanleitung deutsch...
Страница 4: ...www balluff com...
Страница 108: ......
Страница 109: ...BOS R254K UUI RH10 S4 Configuration Guide english...
Страница 110: ...www balluff com...