10
english
3
Overview of IO-Link Data and Functions (continued)
3.2
Device Variants
Variant
Device ID
Baud rate
No. of
PDInput
No. of
PDOutput
IO-Link protocol
version
Minimum cycle
time
Variant 1
0x040B10
COM3 (230.4 kbit/s)
1 byte
1 byte
1.1.2
3 ms
Variant 2
0x040B11
COM3 (230.4 kbit/s)
1 byte
1 byte
1.1.2
3 ms
Variant 3
0x040B12
COM3 (230.4 kbit/s)
17 bytes
1 byte
1.1.2
5 ms
Variant 4
0x040B13
COM3 (230.4 kbit/s)
6 bytes
1 byte
1.1.2
5 ms
Variant 5
0x040B30
COM3 (230.4 kbit/s)
17 bytes
1 byte
1.1.2
5 ms
Tab. 3-1: Device Variants
3.3
Process Data Profiles
Setting the process data profile is described in section 7.7
Process Data Info and Configuration
3.3.1 Variant 1 (AdSS)
PDInput
Byte 0
Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0
Reserved
SSC1 (ADSS1)
PDOutput
Byte 0
Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0
Reserved
Transducer
Enable
3.3.2 Variant 2 (LSSC)
PDInput
Byte 0
Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0
System Err
or
Reserved
Reserved
Signal
Quality Bad
Reserved
Reserved
SSC2 (LSSC2)
SSC1 (LSSC1)
PDOutput
Byte 0
Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0
Reserved
Transducer
Enable
BOS R254K-UUI-RH10-S4
Photoelectric Sensors
Содержание BOS R254K-UUI-RH10-S4
Страница 1: ...deutsch Konfigurationsanleitung english Configuration Guide BOS R254K UUI RH10 S4...
Страница 2: ...www balluff com...
Страница 3: ...BOS R254K UUI RH10 S4 Konfigurationsanleitung deutsch...
Страница 4: ...www balluff com...
Страница 108: ......
Страница 109: ...BOS R254K UUI RH10 S4 Configuration Guide english...
Страница 110: ...www balluff com...