86
english
Value
Name
Analog Output
0x0006 (6)
Switching Counter Value
0x0013 (19)
Switching Speed Value
0x001B (27)
Current Operating Hours
0x001C (28)
Total Operating Hours
0x001D (29)
Custom Operating Hours
0x001E (30)
Boot Cycle Counter
0x001F (31)
Custom Boot Cycle Counter
0x0020 (32)
Current Signal Quality
0x0022 (34)
Optical Transmitter Power
0x0036 (54)
Inclination Deviation Value
0x0042 (66)
Lifetime Extreme Time
0x004A (74)
Vibration Level
0x0050 (80)
Device Temperature
0x0053 (83)
Minimum
0x0054 (84)
Maximum
0x0055 (85)
Average
0x0056 (86)
Moving Average
0xFFF7 (65527) Transducer Signal
Tab. 6-14: Pin assignment – Signal Source
Logic
With
Logic
, the input/output can be configured as inverted
or normal.
Value
Name
Description
0x00 (0)
Normal
Non-inverted logic
0x01 (1)
Inverted
Inverted logic
Tab. 6-15: Pin assignment – Logic
Characteristic
With
Characteristic
, a rising or falling characteristic of the
analog output can be configured.
Value
Name
Description
0x00 (0)
Rising
Rising input value = Rising
output value
0x01 (1)
Falling
Rising input value = Falling
output value
Tab. 6-16: Pin assignment – characteristic
6
System Functions (continued)
Type
The output can be configured with
Type
.
Value
Name
Description
Digital
0x00 (0)
PNP
PNP output
0x01 (1)
NPN
NPN output
0x02 (2)
Push-Pull
Push-Pull output
Analog
0x00 (0)
4…20mA
Analog current output 4 to
20mA
Tab. 6-17: Pin assignment – Type
6.5.3 System Commands
For an overview of all System Commands, see section 3.5
on page 19.
BOS R254K-UUI-LH10-S4
Photoelectric Sensors
Содержание BOS R254K-UUI-LH10-S4
Страница 1: ...deutsch IO Link Konfiguration english IO Link Configuration BOS R254K UUI LH10 S4...
Страница 2: ...www balluff com...
Страница 3: ...BOS R254K UUI LH10 S4 IO Link Konfiguration deutsch...
Страница 4: ...www balluff com...
Страница 99: ...BOS R254K UUI LH10 S4 IO Link Configuration english...
Страница 100: ...www balluff com...
Страница 195: ......