44
english
Speed Monitoring Input
With
Speed Monitoring Input
, the internal binary signal
source can be selected.
Input
contains a list of the internal
binary signals .
Value
Meaning
0x0002 (2)
Digital Input Pin 2
0x0003 (3)
Switching Counter Limit not reached
0x0004 (4)
Switching Counter Limit reached
0x0005 (5)
Switching Counter Limit exceeded
0x0007 (7)
Switching Counter Reset
0x0008 (8)
Signal Delay Channel 1
0x0009 (9)
Signal Delay Channel 2
0x000A (10)
Signal Delay Channel 3
0x000B (11)
Signal Delay Channel 4
0x0010 (16)
Switching Speed ok
0x0011 (17)
Switching Speed too low
0x0012 (18)
Switching Speed too high
0x0014 (20)
Switching Speed Reset
0x0015 (21)
Short Circuit Pin 4
0x0016 (22)
Short Circuit Pin 2
0x0017 (23)
Undervoltage
0x0018 (24)
Overvoltage
0x001A (26)
Cable break pin 2
0x0021 (33)
Signal Quality Bad
0x0023 (35)
Humidity Bad
0x0027 (39)
Transducer Enable
0x002D (45)
Optical Transmitter Error
0x002F (47)
System Error
0x0034 (52)
PDout Invalid
0x0037 (55)
Inclination Alarm Status
0x0038 (56)
ADSS1
0x003A (58)
LSSC1
0x003B (59)
LSSC2
0x003C (60)
LSSC3
0x003D (61)
LSSC4
0x003E (62)
Teach In
0x0041 (65)
Lifetime Extreme
0x0043 (67)
Overload Pin 4
0x0044 (68)
Overload Pin 2
0x004B (75)
Vibration Alarm Status
0x0063 (99)
LOGICBLOCK1_RESULT
0x0064 (100)
LOGICBLOCK2_RESULT
0x0065 (101)
LOGICBLOCK3_RESULT
0x0066 (102)
LOGICBLOCK4_RESULT
Tab. 5-12: Speed Monitoring Input
5
Secondary Device Functions (continued)
Speed Monitoring Mode
With
Speed Monitoring Mode
, the current mode of the
counter function can be selected.
Value
Meaning
Description
0x00 (0) Deactivated
Deactivated
0x01 (1) Speed
Speed monitoring
Tab. 5-13: Speed Monitoring Mode
Speed Upper Limit High
In combination with
Speed Upper Limit Low
, it forms a
threshold value with hysteresis for the
too high
status.
Speed Upper Limit Low
In combination with
Speed Upper Limit High
, it forms a
threshold value with hysteresis for the
too high
status.
Speed Lower Limit High
In combination with
Speed Lower Limit Low
, it forms a
threshold value with hysteresis for the
too low
status.
Speed Lower Limit Low
In combination with
Speed Lower Limit High
, it forms a
threshold value with hysteresis for the
too low
status.
Speed Monitoring Startup Delay
With
Startup Delay
, the time for the startup delay can be
set. The startup delay begins after the supply voltage is
switched on. During the startup delay, speed monitoring
has no function. Speed monitoring starts after the startup
delay has elapsed. The value represents the time in
seconds. The value range is between 0x00 (0) and 0xFF
(255). A value of 0x00 (0) represents no start delay.
Speed Monitoring State
With
Speed Monitoring State
, the current status can be
read.
Value
Meaning
Description
0x00 (0)
Idle
No speed value yet available
0x01 (1)
Too low
Speed value is less than the
lower threshold
0x02 (2)
Ok
Speed value is in the suitable
range
0x04 (4)
Too high
Speed value is greater than
the upper threshold
0x08 (8)
Startup
Delay
Startup delay currently
running
0xFF (255) Deactivated
Feature is deactivated
Tab. 5-14: Speed Monitoring State
BOS R254K-UUI-LH10-S4
Photoelectric Sensors
Содержание BOS R254K-UUI-LH10-S4
Страница 1: ...deutsch IO Link Konfiguration english IO Link Configuration BOS R254K UUI LH10 S4...
Страница 2: ...www balluff com...
Страница 3: ...BOS R254K UUI LH10 S4 IO Link Konfiguration deutsch...
Страница 4: ...www balluff com...
Страница 99: ...BOS R254K UUI LH10 S4 IO Link Configuration english...
Страница 100: ...www balluff com...
Страница 195: ......