Balluff Network Interface EtherNet/IP™
www.balluff.com
20
6
Configuration via Explicit Messages
QuickConnect
The BNI EIP-508-005-E002 module can be launched and connected faster
via the QuickConnect function.
Enabling QuickConnect automatically takes over all necessary port properties on the module:
•
Static IP address
•
Ports at 100 Mbps full-duplex
•
Auto-negotiation disabled
•
Auto MDI-X disabled
•
Prepared for linear topology
You can configure
QuickConnect
via the following
class instance attribute of the explicit messages:
Class
Instance
Attribute
Value
245 (0xF5)
1 (0x01)
12 (0x0C)
0: disabled (default)
1: enabled
Note
For QuickConnect to be enabled, ACD (Address Conflict Detection) must also be
enabled. This is switched on by default.
The
ACD
can be reviewed and changed using the following class instance attributes of the
explicit messages:
Class
Instance
Attribute
Value
245 (0xF5)
1 (0x01)
10 (0x0A)
0: disabled
1: enabled
(default)