Integration
5.2. Address
Specifications
These settings are factory-set.
IP-Adresse: 192.168.1.1
Subnetmaske: 255.255.255.0
Gatewayadresse: 192.168.1.1
5.3. Data
Configuration
Please enter the following values in the control system. They describe the data sizes of the
input, output and configuration data.
Instanc ID
Data length
502
508
507
527
508-C06
Input
100
200
392
196
196
128
Output
101
134
262
130
128
86
CONFIG
102
98
194
98
98
0
5.4. Configuration
Data
The following tables show an allocation of the configuration data sequence. The standard
values specified below describe a configuration with the IO-Link function at Pin 4 and
standard I/O functions at Pin 2 and 4 of each port. The input and output functions of the
configured standard I/O ports are set via the process data.
BNI EIP-502-105-XXXX, BNI EIP-507-005-Z040, BNI EIP-527-005-Z040
Byte
Slot
Module part
Description
0…1
1
Module
General configuration for the entire module
2…25
2
IO-Link port 0
Configuration of IO-Link port 0
26…49
3
IO-Link port 1
Configuration of IO-Link port 1
50…73
4
IO-Link port 2
Configuration of IO-Link port 2
74…97
5
IO-Link port 3
Configuration of IO-Link port 3
BNI EIP-508-X05-XXXX
Byte
Slot
Module part
Description
0…1
1
Module
General configuration for the entire module
2…25
2
IO-Link port 0
Configuration of IO-Link port 0
26…49
3
IO-Link port 1
Configuration of IO-Link port 1
50…73
4
IO-Link port 2
Configuration of IO-Link port 2
74…97
5
IO-Link port 3
Configuration of IO-Link port 3
98…121
6
IO-Link port 4
Configuration of IO-Link port 4
122…145
7
IO-Link port 5
Configuration of IO-Link port 5
146…169
8
IO-Link port 6
Configuration of IO-Link port 6
170…193
9
IO-Link port 7
Configuration of IO-Link port 7
Note
The BNI EIP-508-XXX-XXXX-C06 has no configuration data. These are fixed
and can not be changed.