55
55
english
Read Times in Static
Mode
(Configuration:
without dynamic
mode, without
CRC_16 check)
The indicated times apply after the data carrier has been recognized. Otherwise an additional 45 ms
must be added to allow for the energy field to be established until the data carrier is recognized.
For double read and compare:
Including readback and compare:
n = number of contiguous bytes to write
y = number of blocks to be written
Example:
Read 17 bytes starting at address 187. Data carrier with 32 byte blocks.
Blocks 5 and 6 have to be accessed, because start address 187 is in block 5 and end address 203 is in block 6.
t = 2 * 120 + 17 * 10 = 410
Read/Write Times
Write Times in Static
Mode
(Configuration:
without dynamic
mode, without
CRC_16 check)
Data carrier with 32 byte blocks
Data carrier with 64 byte blocks
No. of bytes
Read time [ms]
No. of bytes
Read time [ms]
from 0 to 31
110
from 0 to 63
220
for each additional
32 bytes add
120
for each additional
64 bytes add
230
from 0 to 255
= 950
from 0 to 2047
= 7350
Data carrier with 32 byte blocks
Data carrier with 64 byte blocks
No. of bytes
Write time [ms]
No. of bytes
Write time [ms]
from 0 to 31
110 + n * 10
from 0 to 63
220 + n * 10
for 32 bytes or more
y * 120 + n * 10
for 64 bytes or more
y * 230 + n * 10
C-6_0-007-00_836905_E_0704.p65
56
english
56
Read Times in
Dynamic Mode
(Configuration:
with dynamic mode,
without CRC_16
check)
Read Times for 1 Block with double read and compare
:
n = Number of contiguous bytes to be written
The indicated times apply after the data carrier has been recognized. Otherwise an additional 45 ms
must be added to allow for the energy field to be established until the data carrier is recognized.
Read/Write Times
m = highest address to be read
Formula:
t = (m + 1) * 3.5 ms
Example: Read 11 bytes starting at address 9. Hence the highest address to be read is 19.
This results in 70 ms.
Including readback and compare:
Write Times in
Dynamic Mode
(Configuration:
with dynamic mode,
without CRC_16
check)
Data carrier with 32 byte blocks
Data carrier with 64 byte blocks
No. of bytes
Read time [ms]
No. of bytes
Read time [ms]
from 0 to 3
14
from 0 to 3
14
for each additional
byte add
3.5
for each additional
byte add
3.5
from 0 to 31
112
from 0 to 63
224
Data carrier with 32 byte blocks
Data carrier with 64 byte blocks
No. of bytes
Write time [ms]
No. of bytes
Write time [ms]
from 0 to 3
14 + n * 10
from 0 to 3
14 + n * 10
for each additional
byte add
3.5
for each additional
byte add
3.5