6.7
System commands
Different commands are implemented in the BIP that can
be reached via parameter
System Command
on
index 2,
subindex 0
. Once a system command is transmitted to the
BIP, the command triggers the desired action, provided
that this action is permitted in the current application state.
Command Name
Description
0x01 (1)
ParamUploadStart
Starts parameter upload.
0x02 (2)
ParamUploadEnd
Ends parameter upload.
0x03 (3)
ParamDownloadStart
Starts parameter download.
0x04 (4)
ParamDownloadEnd
Ends parameter download.
0x05 (5)
ParamDownloadStore
Completes the configuration and starts the data storage.
0x41 (65)
SP1 Single Value Teach
Saves the currently measured position as
Setpoint 1
.
0x42 (66)
SP2 Single Value Teach
Saves the currently measured position as
Setpoint 2
.
0x4E (78)
Teach Reset
Resets all settings (incl. hysteresis) for the selected teach channel.
0x80 (128)
Device Reset
Re-initializes all device components (software reset).
0x82 (130)
Restore Factory Settings
Resets all configurations to the factory setting.
0xA5 (165)
Reset Maintenance
Resets all maintenance values (condition monitor).
0xE0 (224)
Teach Preset
Calculates and saves the PDV offset, sets the current output value to the preset
value.
0xE1 (225)
Teach Measurement
Range Lower Limit
Teaches in the current position as a lower limit value of the measuring range.
0xE2 (226)
Teach Measurement
Range Upper Limit
Teaches in the current position as an upper limit value of the measuring range.
Tab. 6-9: System commands of index 2, subindex 0
6
IO-Link interface (continued)
16
english
BIP LD2-T017-01-EP _ _ / EP _ _ -S4
Inductive Positioning System
Содержание BIP LD2-T017-01-EP-S4 Series
Страница 2: ...www balluff com...
Страница 3: ...BIP LD2 T017 01 EP_ _ BIP LD2 T017 01 EP_ _ S4 Betriebsanleitung deutsch...
Страница 4: ...www balluff com...
Страница 32: ......
Страница 33: ...BIP LD2 T017 01 EP_ _ BIP LD2 T017 01 EP_ _ S4 User s Guide english...
Страница 34: ...www balluff com...
Страница 62: ......
Страница 63: ...BIP LD2 T017 01 EP_ _ BIP LD2 T017 01 EP_ _ S4 Notice d utilisation fran ais...
Страница 64: ...www balluff com...
Страница 92: ......
Страница 93: ...BIP LD2 T017 01 EP_ _ BIP LD2 T017 01 EP_ _ S4 Manuale d uso italiano...
Страница 94: ...www balluff com...
Страница 122: ......
Страница 123: ...BIP LD2 T017 01 EP_ _ BIP LD2 T017 01 EP_ _ S4 Manual de instrucciones espa ol...
Страница 124: ...www balluff com...
Страница 152: ......
Страница 153: ...BIP LD2 T017 01 EP_ _ BIP LD2 T017 01 EP_ _ S4...
Страница 154: ...www balluff com...
Страница 157: ...2 1 BIP IO Link PLC IO Link BIP 2 2 BIP BIP 2 3 2 4 2 www balluff com 5 BIP LD2 T017 01 EP_ _ EP_ _ S4...
Страница 158: ...3 1 3 1 35 25 4 1 15 1 25 31 20 3 5 4 3 2 LED 3 2 BIP IO Link 3 6 BIP LD2 T017 01 EP_ _ EP_ _ S4...
Страница 160: ...4 4 2 4 4 1 2 4 S4 BIP 1 L 18 30 V 2 1 3 L GND 4 C Q 1 4 1 4 3 BIP BIP BIP BIP 20 m 8 BIP LD2 T017 01 EP_ _ EP_ _ S4...
Страница 161: ...5 1 BIP 1 2 3 BIP BIP 5 2 BIP BIP 5 www balluff com 9 BIP LD2 T017 01 EP_ _ EP_ _ S4...
Страница 174: ...6 11 6 11 1 PW SP Custom Operating Total Operating 6 6 3 1 1 2 3 2 3 2 1 6 IO Link 22 BIP LD2 T017 01 EP_ _ EP_ _ S4...
Страница 182: ......
Страница 183: ...BIP LD2 T017 01 EP_ _ BIP LD2 T017 01 EP_ _ S4...
Страница 184: ...www balluff com...
Страница 187: ...2 1 IO Link BIP PLC IO Link BIP 2 2 BIP BIP 2 3 2 4 2 www balluff com 5 BIP LD2 T017 01 EP_ _ EP_ _ S4...
Страница 188: ...3 1 3 1 35 25 4 1 15 1 25 31 20 3 5 4 3 2 LED 3 2 BIP IO Link 3 6 BIP LD2 T017 01 EP_ _ EP_ _ S4...
Страница 191: ...5 1 BIP 1 2 3 BIP BIP 5 2 BIP BIP 5 www balluff com 9 BIP LD2 T017 01 EP_ _ EP_ _ S4...
Страница 204: ...6 11 6 11 1 PW SP 3 2 Custom Operating Total Operating 6 6 3 1 1 2 3 2 3 2 1 6 IO Link 22 BIP LD2 T017 01 EP_ _ EP_ _ S4...