Section 4
Programming and Operation
Programming & Operation 4-1
MN715
Overview
The keypad is used to program the control parameters, to operate the motor and to
monitor the status and outputs of the control by accessing the display options, diagnostic
menus and the fault log.
Figure 4-1 Keypad
JOG -
(Green) lights when Jog is active.
FWD -
(Green) lights when FWD direction is commanded.
REV -
(Green) lights when REV direction is commanded.
STOP - (Red) lights when motor STOP is commanded.
Indicator Lights
Keypad Display -
Displays status
information during Local or Remote
operation. It also displays information
during parameter setup and fault or
Diagnostic Information.
JOG -
Press JOG to select the
preprogrammed jog speed. After the jog
key has been pressed, use the FWD or
REV keys to run the motor in the
direction that is needed. The JOG key is
only active in the local mode.
FWD -
Press FWD to initiate forward
rotation of the motor. (Active in Local
and Jog modes).
REV -
Press REV to initiate reverse
rotation of the motor. (Active in Local
and Jog modes).
STOP -
Press STOP to initiate a stop
sequence. Depending on the setup of the
control, the motor will either regen or
coast to a stop. This key is operational
in all modes of operation unless it has
been disabled by the Keypad Stop
parameter in the Keypad (programming)
Setup Block.
LOCAL -
Press LOCAL to change
between the local (keypad) and remote
operation.
DISP -
Press DISP to return to display
mode from programming mode. Provides
operational status and advances to the
next display menu item.
SHIFT -
Press SHIFT in the program
mode to control cursor movement.
Pressing the SHIFT key once moves the
blinking cursor one character position to
the right. While in program mode, a
parameter value may be reset to the
factory preset value by pressing the
SHIFT key until the arrow symbols at the
far left of the keypad display are flashing,
then press an arrow key. In the display
mode the SHIFT key is used to adjust
the keypad contrast.
RESET -
Press RESET to clear all fault
messages (in local mode). Can also be
used to return to the top of the block
programming menu without saving any
parameter value changes.
PROG -
Press PROG to enter the
program mode. While in the program
mode the PROG key is used to edit a
parameter setting.
-
(UP Arrow).
Press
to change the value of the
parameter being displayed. Pressing
increments the value to the next greater
value. Also, when the fault log or
parameter list is displayed, the
key will
scroll upward through the list. In the
local mode pressing the
key will
increase motor speed to the next greater
value.
-
(Down Arrow)
Press
to change the value of the
parameter being displayed. Pressing
decrements the value to the next lesser
value. Also, when the fault log or
parameter list is displayed, the
key will
scroll downward through the list. In the
local mode pressing the
key will
decrease motor speed to the next lesser
value.
ENTER -
Press ENTER to save
parameter value changes and move
back to the previous level in the
programming menu. In the display mode
the ENTER key is used to directly set the
local speed reference. It is also used to
select other operations when prompted
by the keypad display.
Содержание -W
Страница 1: ...SERIES 15H Inverter Control Installation Operating Manual 2 01 MN715 ADJUSTABLE SPEED DRIVE ...
Страница 51: ...3 40 Receiving Installation MN715 ...
Страница 128: ...Appendix C Appendix C 1 MN715 ...