background image

Section 2

General Information

General Information 2-1

MN2411

Thank you for purchasing your Baldor Generator Set. This manual contains information you need to safely and efficiently

install and operate your generator set. During the preparation of this manual every effort was made to ensure the

accuracy of its contents. This manual describes only very basic engine information. A separate owner’s manual for the

engine is supplied with this unit for your use. Please refer to the engine manual for information relative to engine

operation, maintenance, recommendations and additional safety warnings.
Copyright Baldor

E

2004. All rights reserved.

This manual is copyrighted and all rights are reserved. This document may not, in whole or in part, be copied or

reproduced in any form without the prior written consent of Baldor Electric Company, Inc.
Baldor Generators have earned the reputation of being high quality and dependable. We take pride in this fact and

continue to keep our quality standards high on our list of priorities. We are also constantly researching new technological

ideas to determine if they could be used to make our generator sets even better.
Baldor makes no representations or warranties with respect to the contents hereof and specifically disclaims any implied

warranties of fitness for any particular purpose. The information in this document is subject to change without notice.

Baldor assumes no responsibility for any errors that may appear in this document.

Limited Warranty

Baldor Generators will replace or repair free of charge any part or parts of the generator of their manufacture that are

defective in workmanship and materials for a period of time as set forth in the Warranty Period chart below. All Baldor

products requiring warranty service shall be transported or shipped freight pre--paid, at the risk of the party requiring

warranty service, to a Baldor Generator repair facility, or to Baldor Generators’ Customer Service Department. Written

notification of the alleged defect in addition to a description of the manner in which the Baldor generator is used, and the

name, address and telephone number of the party requiring warranty service must be included. Baldor is not responsible

for removal and shipment of the Baldor product to the service center or for the reinstallation of the Baldor product upon its

return to the party requiring warranty service. Problems with Baldor products can be due to improper maintenance, faulty

installation, non--Baldor additions or modifications, or other problems not due to defects in Baldor workmanship or

materials. If a Baldor Generator repair facility determines that the problem with a Baldor product is not due to defects in

Baldor workmanship or materials, then the party requesting warranty service will be responsible for the cost of any

necessary repairs. EXCEPT FOR THE EXPRESSED WARRANTY SET FORTH ABOVE, BALDOR GENERATORS

DISCLAIMS ALL OTHER EXPRESSED AND IMPLIED WARRANTIES INCLUDING THE IMPLIED WARRANTIES OF

FITNESS FOR A PARTICULAR PURPOSE AND MERCHANTABILITY. NO OTHER WARRANTY, EXPRESSED OR

IMPLIED, WHETHER OR NOT SIMILAR IN NATURE TO ANY OTHER WARRANTY PROVIDED HEREIN, SHALL

EXIST WITH RESPECT TO THE GOODS SOLD UNDER THE PROVISIONS OF THESE TERMS AND CONDITIONS.

ALL OTHER SUCH WARRANTIES ARE HEREBY EXPRESSLY WAIVED BY THE BUYER. UNDER NO

CIRCUMSTANCES SHALL BALDOR GENERATORS BE LIABLE OR RESPONSIBLE IN ANY MANNER WHATSOEVER

FOR ANY INCIDENTAL, CONSEQUENTIAL OR PUNITIVE DAMAGES, OR ANTICIPATED PROFITS RESULTING

FROM THE DEFECT, REMOVAL, REINSTALLATION, SHIPMENT OR OTHERWISE. This is the sole warranty of Baldor

Generators and no other affirmations or promises made by Baldor Generators shall be deemed to create an expressed or

implied warranty. Baldor Generators has not authorized anyone to make any representations or warranties other than the

warranty contained herein.

Warranty Period

Generator Series

Labor*

Parts

Portable Products (Premier, Powerchief,

DG Series, K Series)

1 Year

3 Years

Towable Products (TS)

1 Year or 3,000 Hours

Whichever comes first

3 Years or 3,000 Hours

Whichever comes first

POW’R LITE Light Towers

1 Year or 3,000 Hours

Whichever comes first

3 Years or 3,000 Hours Whichever comes first

Excluded from any warranty coverage regardless of

time period: Light Fixture, Lamps and Ballasts

3600 RPM Standby Systems

(Some AE Models)

1 Year or 1,000 Hours

Whichever comes first

3 Years or 1,000 Hours

Whichever comes first

1800 RPM Standby Systems

(Some AE Models, DLC, GLC)

1 Year or 3,000 Hours

Whichever comes first

3 Years or 3,000 Hours

Whichever comes first

Industrial Standby Systems

1 Year or 1,000 Hours

Whichever comes first

2 Years or 1,000 Hours

Whichever comes first

Industrial Prime Power Systems

1 Year or 1,000 Hours

Whichever comes first

1 Year or 1,000 Hours

Whichever comes first

International

1 Year or 1,000 Hours

Whichever comes first

1 Year or 1,000 Hours

Whichever comes first

*For products covered under labor coverage, travel expenses will be allowed up to 7 hours straight labor or 300 miles,

whichever occurs first and only applies to permanently wired and mounted products (AE, DLC, GLC, IDLC).

No warranty registration card is necessary to obtain warranty on Baldor Generators.

You must save the purchase receipt. Proof of purchase, date, serial number and model number will be required for all

portable and Towable products to qualify for any warranty consideration.

For all other products, a start--up inspection form/warranty registration must be completed in its entirety and submitted to

Baldor Generators within 30 days of start--up to qualify for any warranty consideration.

Содержание PC1100R

Страница 1: ...PC1100R PC1700RI Portable Generator Installation Operating Manual 5 05 MN2411...

Страница 2: ...hemicals known to the state of California to cause cancer birth defects and other reproductive harm WARNING CALIFORNIA PROPOSITION 65 WARNING Battery posts terminals and related accessories are known...

Страница 3: ...n 3 2 Installation 3 2 Electrical Connections 3 2 Frame Ground Connection 3 3 Engine Oil 3 3 Use of Electric Motor Loads 3 4 Section 4 Operation 4 1 Operator Control Panel 4 1 Pre Start Checks 4 3 Sta...

Страница 4: ...ii Table of Contents MN2411...

Страница 5: ...ipment at all times Keep non qualified personnel at a safe distance from this equipment Only qualified personnel familiar with the safe installation operation and maintenance of this device should att...

Страница 6: ...d can cause fire explosions injury or death WARNING Make sure the fuel cap is completely and securely closed after refueling to prevent spillage Gasoline and diesel fuel are flammable and can cause fi...

Страница 7: ...erate machinery when physically or mentally fatigued or while under the influence of alcohol drugs or medication WARNING Never operate the engine when the air cleaner is removed An engine backfire can...

Страница 8: ...NING Place protective covers over all rotating parts such as drive shaft pulley belt etc Rotating parts cause extremely dangerous situations because they can catch loose clothing or extremities and ca...

Страница 9: ...e tab will cause a direct short to the generator windings and cause possible generator damage Caution Avoid installing the generator set beside heat generating equipment or directly below water or ste...

Страница 10: ...1 6 Product Safety Information MN2411...

Страница 11: ...Baldor workmanship or materials then the party requesting warranty service will be responsible for the cost of any necessary repairs EXCEPT FOR THE EXPRESSED WARRANTY SET FORTH ABOVE BALDOR GENERATOR...

Страница 12: ...2 2 General Information MN2411...

Страница 13: ...g the Generator The generator weighs about 55 lbs dry Use proper lift equipment and methods to avoid injury Figure 3 1 PC17RI Portable Generator AUTO POWER SAVE PILOT LAMP OVER LOAD ON OFF STOP RUN CH...

Страница 14: ...electrical equipment should be protected from excessive moisture Failure to do so will result in deterioration of the insulation and may result in short circuits and a possible electrocution hazard I...

Страница 15: ...ire normally 6 AWG as required by NEC and local codes The local reference ground is normally a copper clad earth ground rod driven into the earth at least 8 feet Figure 3 2 Frame Ground Connection Eng...

Страница 16: ...ther factors that influence the amount of current needed to start a motor are 1 The type of load connected to the motor If the electric motor is connected to a hard starting load such as an air compre...

Страница 17: ...when generator is running and an overload condition exists If Overload Lamp is ON Stop the generator and Start the generator again to resume operation Oil Level Lamp Lamp is on when engine oil level i...

Страница 18: ...o not allow a spark or open flame to be present during battery charging Always turn off the generator before disconnecting the battery leads from the DC Output terminals to avoid a spark S The battery...

Страница 19: ...e engine 3 Pull lightly on the recoil grip until you feel significant resistance then pull sharply Allow the recoil to gently rewind into the recoil housing Do not allow the recoil rope to snap back i...

Страница 20: ...4 4 Operation MN2411...

Страница 21: ...Stop engine and allow engine to cool before refueling Gasoline and diesel fuel are flammable and can cause fire explosions injury or death Check Fuel Level Right side cover 1 Remove fuel filler cap 2...

Страница 22: ...air flow 3 Clean the generator set and its components with a damp cloth or sponge Never use a water hose or pressure washer as this may damage electrical components 4 Inspect and replace any control...

Страница 23: ...tery Never Jump Start Engine starts but will not run smoothly Fuel or ignition problem Have engine serviced Engine overheats Excessive load Debris or dirt buildup on engine Remove one or more electric...

Страница 24: ...arise from sitting idle Please follow this procedure prior to storing the unit This will help to ensure that the generator will start and provide good service when it is removed from storage 1 Remove...

Страница 25: ...041 PHONE 713 895 7062 FAX 713 690 4540 DALLAS 3040 QUEBEC DALLAS TX 75247 PHONE 214 634 7271 FAX 214 634 8874 UTAH SALT LAKE CITY 2230 SOUTH MAIN STREET SALT LAKE CITY UT 84115 PHONE 801 832 0127 FAX...

Страница 26: ...RNIA PROPOSITION 65 WARNING Engine exhaust from this product contains chemicals known to the state of California to cause cancer birth defects and other reproductive harm WARNING CALIFORNIA PROPOSITIO...

Отзывы: