background image

Product Safety Information 1-5

MN2411

Warning Statements

  Continued

Maintenance
WARNING: Before cleaning, inspecting, repairing, refueling or performing any maintenance to the

generator set, always be sure the engine has stopped and that all rotating parts have also

stopped.  After stopping, certain components are still extremely hot so be careful not to get

burned.

WARNING: Before servicing the generator set, be sure to disconnect the spark plug wires to prevent

accidental engine rotation or starting.

WARNING: Inspect all wiring frequently and replace any damaged, broken or frayed wiring or wires with

damaged insulation immediately.  Electrical shock can cause serious or fatal injury.

WARNING: Disconnect all electrical wires and load devices from generator power outlets before servicing

the generator.  Electrical shock can cause serious or fatal injury.  Always treat electrical

circuits as if they are energized.

WARNING: Check fuel tank, fuel line, and connections monthly for fuel leaks.  Gasoline is flammable and

can cause fire, explosions, injury or death.  If a leak is found, replace only with approved pipe

or components.

WARNING: Never store an engine with fuel in its tank indoors or in an enclosed, poorly ventilated area

where gasoline fumes could reach an ignition source and cause an explosion.

Caution Statements

Caution:

The brass connecting tab on some 120VAC duplex receptacles have been removed.  Each

receptacle is powered by a separate generator winding.  When replacing a receptacle, inspect

the brass tab that normally links both receptacles.  If it is removed, be sure to remove the

brass tab from the replacement receptacle before it is installed.  Failure to remove the tab will

cause a direct short to the generator windings and cause possible generator damage.

Caution:

Avoid installing the generator set beside heat generating equipment, or directly below water

or steam pipes or in the vicinity of corrosive substances or vapors, metal particles and dust.

Heat can cause engine problems to develop and unwanted substances can cause rust or

generator failure over time.

Caution:

Do not apply high voltage to windings (start the generator) in a moisture

saturated condition.

Moisture can cause insulation breakdown, making it necessary to return the generator to the

factory for repair, and consequent expense and loss of time.

Caution:

Use only original equipment or authorized replacement parts.  Using the correct parts will

assure continued safe operation as designed.

Caution:

Do not suspend the generator from the top handle during operation.

Caution:

Do not tamper with or change the engine speed.  Engine speed is factory set to produce the

correct voltage and output frequency.

Caution:

Never operate the engine without a muffler and spark arrestor.  The engine is designed to

have the correct exhaust components installed.  Operating without these components can

present a fire hazard, cause excessive exhaust gases and cause damage to engine.

Caution:

Operate the generator only on a level surface.  Operation of the generator on an incline or

slope may degrade engine lubrication and result in engine failure.

Caution:

Always fill fuel tank with clean fresh fuel before use.  Never leave fuel in tank for long storage

periods. Old fuel becomes stale and can damage the fuel system causing the engine not to

start.  Always drain the fuel tank after use before storage.

Caution:

For electric start models, do not place the key switch in the start position when engine is

running.  This causes the starting motor to engage and may damage the starter and engine.

Содержание PC1100R

Страница 1: ...PC1100R PC1700RI Portable Generator Installation Operating Manual 5 05 MN2411...

Страница 2: ...hemicals known to the state of California to cause cancer birth defects and other reproductive harm WARNING CALIFORNIA PROPOSITION 65 WARNING Battery posts terminals and related accessories are known...

Страница 3: ...n 3 2 Installation 3 2 Electrical Connections 3 2 Frame Ground Connection 3 3 Engine Oil 3 3 Use of Electric Motor Loads 3 4 Section 4 Operation 4 1 Operator Control Panel 4 1 Pre Start Checks 4 3 Sta...

Страница 4: ...ii Table of Contents MN2411...

Страница 5: ...ipment at all times Keep non qualified personnel at a safe distance from this equipment Only qualified personnel familiar with the safe installation operation and maintenance of this device should att...

Страница 6: ...d can cause fire explosions injury or death WARNING Make sure the fuel cap is completely and securely closed after refueling to prevent spillage Gasoline and diesel fuel are flammable and can cause fi...

Страница 7: ...erate machinery when physically or mentally fatigued or while under the influence of alcohol drugs or medication WARNING Never operate the engine when the air cleaner is removed An engine backfire can...

Страница 8: ...NING Place protective covers over all rotating parts such as drive shaft pulley belt etc Rotating parts cause extremely dangerous situations because they can catch loose clothing or extremities and ca...

Страница 9: ...e tab will cause a direct short to the generator windings and cause possible generator damage Caution Avoid installing the generator set beside heat generating equipment or directly below water or ste...

Страница 10: ...1 6 Product Safety Information MN2411...

Страница 11: ...Baldor workmanship or materials then the party requesting warranty service will be responsible for the cost of any necessary repairs EXCEPT FOR THE EXPRESSED WARRANTY SET FORTH ABOVE BALDOR GENERATOR...

Страница 12: ...2 2 General Information MN2411...

Страница 13: ...g the Generator The generator weighs about 55 lbs dry Use proper lift equipment and methods to avoid injury Figure 3 1 PC17RI Portable Generator AUTO POWER SAVE PILOT LAMP OVER LOAD ON OFF STOP RUN CH...

Страница 14: ...electrical equipment should be protected from excessive moisture Failure to do so will result in deterioration of the insulation and may result in short circuits and a possible electrocution hazard I...

Страница 15: ...ire normally 6 AWG as required by NEC and local codes The local reference ground is normally a copper clad earth ground rod driven into the earth at least 8 feet Figure 3 2 Frame Ground Connection Eng...

Страница 16: ...ther factors that influence the amount of current needed to start a motor are 1 The type of load connected to the motor If the electric motor is connected to a hard starting load such as an air compre...

Страница 17: ...when generator is running and an overload condition exists If Overload Lamp is ON Stop the generator and Start the generator again to resume operation Oil Level Lamp Lamp is on when engine oil level i...

Страница 18: ...o not allow a spark or open flame to be present during battery charging Always turn off the generator before disconnecting the battery leads from the DC Output terminals to avoid a spark S The battery...

Страница 19: ...e engine 3 Pull lightly on the recoil grip until you feel significant resistance then pull sharply Allow the recoil to gently rewind into the recoil housing Do not allow the recoil rope to snap back i...

Страница 20: ...4 4 Operation MN2411...

Страница 21: ...Stop engine and allow engine to cool before refueling Gasoline and diesel fuel are flammable and can cause fire explosions injury or death Check Fuel Level Right side cover 1 Remove fuel filler cap 2...

Страница 22: ...air flow 3 Clean the generator set and its components with a damp cloth or sponge Never use a water hose or pressure washer as this may damage electrical components 4 Inspect and replace any control...

Страница 23: ...tery Never Jump Start Engine starts but will not run smoothly Fuel or ignition problem Have engine serviced Engine overheats Excessive load Debris or dirt buildup on engine Remove one or more electric...

Страница 24: ...arise from sitting idle Please follow this procedure prior to storing the unit This will help to ensure that the generator will start and provide good service when it is removed from storage 1 Remove...

Страница 25: ...041 PHONE 713 895 7062 FAX 713 690 4540 DALLAS 3040 QUEBEC DALLAS TX 75247 PHONE 214 634 7271 FAX 214 634 8874 UTAH SALT LAKE CITY 2230 SOUTH MAIN STREET SALT LAKE CITY UT 84115 PHONE 801 832 0127 FAX...

Страница 26: ...RNIA PROPOSITION 65 WARNING Engine exhaust from this product contains chemicals known to the state of California to cause cancer birth defects and other reproductive harm WARNING CALIFORNIA PROPOSITIO...

Отзывы: