background image

Product Safety Information 1-3

MN2411

Operation Warning Statements

  Continued

WARNING: Some parts of this generator rotate during operation.  Rotating parts can present extreme

danger if clothing or body extremities are caught by the rotating part and can cause serious

or fatal injury.  Never touch a part of the generator until the engine has been stopped and all

rotating parts are completely stopped.  Also, disconnect the spark plug wires and battery

connection to prevent accidental engine rotation during servicing.

WARNING: Be sure that you understand how to stop the engine quickly in case of an emergency situation.

Become familiar with the controls and safety systems provided with this generator set.

WARNING: Always wear safety glasses with side shields and hearing protection when working near the

generator.

WARNING: Improper operation may cause violent motion of connected equipment.  Be certain that

unexpected movement will not cause injury to personnel or damage to equipment.

WARNING: Never operate the generator set indoors or in a poorly ventilated area such as a tunnel or

cave.  Exhaust fumes are extremely dangerous to all personnel that are in or in contact with

that area.

WARNING: Never permit anyone to operate the generator without proper instructions.  Be sure to keep a copy

of this manual with the generator so that all users can be properly informed of its safe operation.

WARNING: Never allow children or pets to be in the area where the generator is running.  The generator

and the equipment being powered by the generator may cause injury or death.

WARNING: Never operate the generator unless all guards, covers, shields and other safety items are

properly installed.

WARNING: Do not put hands, feet, tools clothing or other objects near rotating parts such as drive shaft,

pulley, belt etc.  Rotating parts cause extremely dangerous situations because they can catch

loose clothing or extremities and cause serious or fatal injury.

WARNING: When operating this generator remain alert at all times.  Never operate machinery when

physically or mentally fatigued, or while under the influence of alcohol, drugs or medication.

WARNING: Never operate the engine when the air cleaner is removed.  An engine backfire can cause

serious burns.

WARNING: High voltage is present whenever engine is running.  Electrical shock can cause serious or

fatal injury.  Never operate electrical equipment while standing in water, on wet ground or with

wet hands, feet or shoes or while barefoot.

WARNING: High voltage is present whenever the engine is running.  Electrical shock can cause serious

or fatal injury.

WARNING: Do not smoke near generator during operation or while refueling.  Gasoline and diesel fuel are

flammable and can cause fire, explosions, injury or death.

WARNING: Stop engine and allow engine to cool before refueling.  Gasoline and diesel fuel are flammable

and can cause fire, explosions, injury or death.

WARNING: Never store an engine with fuel in its tank indoors or in an enclosed, poorly ventilated area

where gasoline fumes could reach an ignition source and cause an explosion.   Fumes may

reach an open flame, electrical spark or pilot light as on a furnace, water heater, clothes dryer,

etc.  Gasoline and diesel fuel are flammable and can cause fire, explosions, injury or death.

WARNING: Allow generator to cool before transporting it or storing it.  Always drain fuel from tank after

generator has cooled.

WARNING: When transporting the generator (especially over rough roads) always drain the fuel tank to

prevent leakage or spillage of fuel.  Gasoline and diesel fuel are flammable and can cause fire,

explosions, injury or death.

WARNING: Operate the generator only on a level surface.  If the generator is tilted during operation, fuel

spillage may result.  Gasoline and diesel fuel are flammable and can cause fire, explosions,

injury or death.

WARNING: Keep generator at least three feet away from buildings and other structures.
WARNING: Keep generator away from flammable or hazardous materials (trash, rags, lubricants,

explosives, paints etc.) and grass or leaf build up.

WARNING: Keep a fire extinguisher near the generator while generator is in use.  An extinguisher rated

“ABC” by the National Fire Protection Association is appropriate.

Continued on next page.

Содержание PC1100R

Страница 1: ...PC1100R PC1700RI Portable Generator Installation Operating Manual 5 05 MN2411...

Страница 2: ...hemicals known to the state of California to cause cancer birth defects and other reproductive harm WARNING CALIFORNIA PROPOSITION 65 WARNING Battery posts terminals and related accessories are known...

Страница 3: ...n 3 2 Installation 3 2 Electrical Connections 3 2 Frame Ground Connection 3 3 Engine Oil 3 3 Use of Electric Motor Loads 3 4 Section 4 Operation 4 1 Operator Control Panel 4 1 Pre Start Checks 4 3 Sta...

Страница 4: ...ii Table of Contents MN2411...

Страница 5: ...ipment at all times Keep non qualified personnel at a safe distance from this equipment Only qualified personnel familiar with the safe installation operation and maintenance of this device should att...

Страница 6: ...d can cause fire explosions injury or death WARNING Make sure the fuel cap is completely and securely closed after refueling to prevent spillage Gasoline and diesel fuel are flammable and can cause fi...

Страница 7: ...erate machinery when physically or mentally fatigued or while under the influence of alcohol drugs or medication WARNING Never operate the engine when the air cleaner is removed An engine backfire can...

Страница 8: ...NING Place protective covers over all rotating parts such as drive shaft pulley belt etc Rotating parts cause extremely dangerous situations because they can catch loose clothing or extremities and ca...

Страница 9: ...e tab will cause a direct short to the generator windings and cause possible generator damage Caution Avoid installing the generator set beside heat generating equipment or directly below water or ste...

Страница 10: ...1 6 Product Safety Information MN2411...

Страница 11: ...Baldor workmanship or materials then the party requesting warranty service will be responsible for the cost of any necessary repairs EXCEPT FOR THE EXPRESSED WARRANTY SET FORTH ABOVE BALDOR GENERATOR...

Страница 12: ...2 2 General Information MN2411...

Страница 13: ...g the Generator The generator weighs about 55 lbs dry Use proper lift equipment and methods to avoid injury Figure 3 1 PC17RI Portable Generator AUTO POWER SAVE PILOT LAMP OVER LOAD ON OFF STOP RUN CH...

Страница 14: ...electrical equipment should be protected from excessive moisture Failure to do so will result in deterioration of the insulation and may result in short circuits and a possible electrocution hazard I...

Страница 15: ...ire normally 6 AWG as required by NEC and local codes The local reference ground is normally a copper clad earth ground rod driven into the earth at least 8 feet Figure 3 2 Frame Ground Connection Eng...

Страница 16: ...ther factors that influence the amount of current needed to start a motor are 1 The type of load connected to the motor If the electric motor is connected to a hard starting load such as an air compre...

Страница 17: ...when generator is running and an overload condition exists If Overload Lamp is ON Stop the generator and Start the generator again to resume operation Oil Level Lamp Lamp is on when engine oil level i...

Страница 18: ...o not allow a spark or open flame to be present during battery charging Always turn off the generator before disconnecting the battery leads from the DC Output terminals to avoid a spark S The battery...

Страница 19: ...e engine 3 Pull lightly on the recoil grip until you feel significant resistance then pull sharply Allow the recoil to gently rewind into the recoil housing Do not allow the recoil rope to snap back i...

Страница 20: ...4 4 Operation MN2411...

Страница 21: ...Stop engine and allow engine to cool before refueling Gasoline and diesel fuel are flammable and can cause fire explosions injury or death Check Fuel Level Right side cover 1 Remove fuel filler cap 2...

Страница 22: ...air flow 3 Clean the generator set and its components with a damp cloth or sponge Never use a water hose or pressure washer as this may damage electrical components 4 Inspect and replace any control...

Страница 23: ...tery Never Jump Start Engine starts but will not run smoothly Fuel or ignition problem Have engine serviced Engine overheats Excessive load Debris or dirt buildup on engine Remove one or more electric...

Страница 24: ...arise from sitting idle Please follow this procedure prior to storing the unit This will help to ensure that the generator will start and provide good service when it is removed from storage 1 Remove...

Страница 25: ...041 PHONE 713 895 7062 FAX 713 690 4540 DALLAS 3040 QUEBEC DALLAS TX 75247 PHONE 214 634 7271 FAX 214 634 8874 UTAH SALT LAKE CITY 2230 SOUTH MAIN STREET SALT LAKE CITY UT 84115 PHONE 801 832 0127 FAX...

Страница 26: ...RNIA PROPOSITION 65 WARNING Engine exhaust from this product contains chemicals known to the state of California to cause cancer birth defects and other reproductive harm WARNING CALIFORNIA PROPOSITIO...

Отзывы: