www.baldormotion.com
8-6 Specifications
MN1919
8.1.12 Encoder output (simulated) (X7)
Unit
All models
Signal
RS422
Resolution
with encoder input on X8
with SSI encoder input on X8
Output is a copy of the input on
X8.
Adjustable simulated output.
See section 4.1.4.
8.1.13 Serial RS232/RS485 interface (X6)
Unit
All models
Signal
RS232, non-isolated CTS/RTS
or
RS485, non-isolated
(model dependent)
Bit rate
baud
9600, 19200, 38400,
57600 (default)
8.1.14 Environmental
All models
Unit
All models
Operating temperature range*
°C
°F
Minimum
Maximum
Derate
+0
+45
See sections
3.2.2 to 3.2.6
+32
+113
See sections
3.2.2 to 3.2.6
Storage temperature range*
-40 to +85
-40 to +185
Humidity
(maximum)
*
%
93
1A, 3A
6A
9A
Forced air cooling flow
(vertical, from bottom to top)
m/s
None required
1
2.5
Maximum installation altitude
(above m.s.l.)
m
ft
1000
Derate 1.1% / 100m over 1000m
3300
Derate 1.1% / 330ft over 3300ft
Shock*
10G
Vibration*
1G, 10-150Hz
IP rating
IP20**
Содержание MicroFlex
Страница 1: ...MicroFlex Servo Control SERVO DRIVE Installation Manual 03 10 MN1919...
Страница 2: ......
Страница 12: ...www baldormotion com 1 6 General Information MN1919...
Страница 16: ...www baldormotion com 2 4 Introduction MN1919...
Страница 40: ...www baldormotion com 3 24 Basic Installation MN1919...
Страница 70: ...www baldormotion com 5 18 Input Output MN1919...
Страница 82: ...www baldormotion com 6 12 Configuration MN1919...
Страница 94: ...www baldormotion com 8 8 Specifications MN1919...
Страница 120: ...Index MN1919...
Страница 122: ...Comments MN1919 Thank you for taking the time to help us...
Страница 123: ......