www.baldormotion.com
Specifications 8-3
MN1919
8.1.2 24VDC control circuit supply input (X2)
Unit
1A
3A
6A
9A
Nominal input voltage
VDC
24
Minimum input voltage
20
Maximum input voltage
30
Maximum ripple
%
±10
Maximum continuous current @24VDC
A
0.6
Power on surge current (typical)
@24VDC, 100ms
A
4
8.1.3 Motor output power (X1)
Unit
1A
3A
6A
9A
Nominal phase current
A
RMS
1
3
6
9
Peak phase current
for 3s
A
RMS
2
6
12
18
Nominal output
@ 230V, 3
Φ
VA
398
1195
2390
3585
Output voltage range (line-line)
@VDC-bus=320V
V
RMS
0 - 230
Output frequency
Hz
0 - 2000
Output dv/dt
at drive, phase-phase
at drive, phase-ground
at motor (using 20m cable), phase-phase
at motor (using 20m cable), phase-ground
kV/
μ
s
2
1.1
1.9
1.8
Nominal switching frequency
kHz
8.0
Minimum motor inductance
(per winding)
mH
1
Efficiency
%
>95
8.1.4 Regeneration (X1)
Unit
1A
3A
6A
9A
Nominal switching threshold (typical)
VDC
on: 388, off: 376
Nominal power
(10% power cycle, R=57
Ω
)
kW
0.25
Peak power
(10% power cycle, R=57
Ω
)
kW
2.7
Maximum regeneration switching current
A
PK
10
Minimum load resistance
Ω
39
Maximum load inductance
μ
H
100
Содержание MicroFlex
Страница 1: ...MicroFlex Servo Control SERVO DRIVE Installation Manual 03 10 MN1919...
Страница 2: ......
Страница 12: ...www baldormotion com 1 6 General Information MN1919...
Страница 16: ...www baldormotion com 2 4 Introduction MN1919...
Страница 40: ...www baldormotion com 3 24 Basic Installation MN1919...
Страница 70: ...www baldormotion com 5 18 Input Output MN1919...
Страница 82: ...www baldormotion com 6 12 Configuration MN1919...
Страница 94: ...www baldormotion com 8 8 Specifications MN1919...
Страница 120: ...Index MN1919...
Страница 122: ...Comments MN1919 Thank you for taking the time to help us...
Страница 123: ......