www.baldormotion.com
8-4 Specifications
MN1919
8.1.5 Analog input (X3)
Unit
All models
Type
Differential
Common mode voltage range
VDC
±10
Common mode rejection
dB
>40
Input impedance
k
Ω
>30
Input ADC resolution
bits
12
Equivalent resolution
mV
±4.9
Sampling interval
μ
s
125
8.1.6 Digital inputs - drive enable and general purpose (X3)
Unit
All models
Type
Opto-isolated inputs
Input voltage
Nominal
Minimum
Maximum
VDC
24
12
30
Input current
(@ Vin=24V)
mA
6.7
Sampling interval
ms
0.5
Maximum pulse input frequency
MHz
1
Minimum pulse width
μ
s
5
8.1.7 Step and Direction inputs (X3)
Unit
All models
Type
Non-isolated DC inputs
Input voltage
VDC
5
Input current
(maximum, per input)
μ
A
20
Maximum step input frequency
MHz
1
Minimum pulse width
ns
250