www.baldormotion.com
Input / Output 5-7
MN1919
5.3.2 General purpose digital input - X3
Location
Connector X3, pins 4 & 5
(Mating connector: Weidmüller Minimate B2L 3.5/14)
Name
DIN0
Description
General purpose optically isolated digital input.
Nominal input voltage: +24VDC
(input current not to exceed 50mA)
Sampling interval:
500
μ
s
The general purpose digital input is buffered by a TLP280 opto-isolator, allowing the input
signal to be connected with either polarity. The state of the digital input is displayed in the Mint
WorkBench Spy window. The input can be can be configured for different user definable
functions.
DIN0+
100R
TLP280
DGND
Mint
10k
Vcc
MicroFlex
DIN0-
3k3
74AHC14
4n7
4n7
5
4
Figure 30 - General purpose digital input circuit
When the MicroFlex is connected to Mint WorkBench, the digital input can be configured using
the Operating Mode Wizard. Alternatively, the Mint keywords
RESETINPUT
,
ERRORINPUT
and
STOPINPUT
can be used in the command window. See the Mint help file for details.
The state of the digital input can be viewed using the Spy window’s Axis tab.
4
5
Содержание MicroFlex
Страница 1: ...MicroFlex Servo Control SERVO DRIVE Installation Manual 03 10 MN1919...
Страница 2: ......
Страница 12: ...www baldormotion com 1 6 General Information MN1919...
Страница 16: ...www baldormotion com 2 4 Introduction MN1919...
Страница 40: ...www baldormotion com 3 24 Basic Installation MN1919...
Страница 70: ...www baldormotion com 5 18 Input Output MN1919...
Страница 82: ...www baldormotion com 6 12 Configuration MN1919...
Страница 94: ...www baldormotion com 8 8 Specifications MN1919...
Страница 120: ...Index MN1919...
Страница 122: ...Comments MN1919 Thank you for taking the time to help us...
Страница 123: ......