2-14 Installation
2 Wire Run/Stop Connections
Parameter 21 - Operating Mode = 2 or 3
Parameter 41 - Accel/Decel/Coast select = 0, 1, 2, 4, 5 or 6
CM
FWD
REV
PS3
PS2
PS1
V+
MOL
Shield
Forward
Reverse
Speed Select
Speed Select
Speed Select
J19
Pull–Up Logic
CM
FWD
REV
PS3
PS2
PS1
V+
MOL
Shield
Forward
Reverse
Speed Select
Speed Select
Speed Select
J19
Pull–Down Logic
See recommended tightening torques for terminal connectors.
Speed Select
PS3
PS2
PS1
Function
Open
Open
Open
Keypad or
Analog Command Input
Open
Open
Closed
33 - Preset Speed #1
Open
Closed
Open
34 - Preset Speed #2
Open
Closed
Closed
35 - Preset Speed #3
Closed
Open
Open
36 - Preset Speed #4
Closed
Open
Closed
37 - Preset Speed #5
Closed
Closed
Open
38 - Preset Speed #6
Closed
Closed
Closed
32 - Max Output Frequency
Содержание ID10101-E
Страница 1: ...Series 10 Inverter Control Installation and Operating Manual 2 00 MN710 AC INVERTER ...
Страница 13: ...1 8 General Information ...
Страница 35: ...2 22 Installation ...
Страница 67: ...4 6 Troubleshooting ...
Страница 68: ...Section 5 Illustrations Illustrations 5 1 ...
Страница 69: ...5 2 Illustrations ...
Страница 70: ...Illustrations 5 3 3 5 HP NEMA 1 230 460VAC ...
Страница 71: ...5 4 Illustrations ...