A-2 Parameters
Parameter List – Continued
Param
No.
Parameter Description
Adj.
Range
Factory
Setting
User
Setting
47
DC brake time
0-5sec
0.2sec
48
DC brake voltage
0-15%
Factory
Set
51
V/Hz profile
0-5
0
52
Torque boost
0-25%
Factory
Set
53
Control base frequency
26-960Hz
60Hz
59
Maximum output volts
185-
480Volts
Factory
Set
61
Load torque limit FWD
30-150%
150%
62
Load torque limit REV
30-150%
150%
63
Regen torque limit FWD
30-150%
80%
64
Regen torque limit REV
30-150%
80%
65
Slip comp adj.
0-12%
0%
67
Time overload trip
0-100%
0%
68
Number of restarts
0-8
0
69
Restart delay
0-60sec
0sec
70
Analog output scale
0-255
Factory
Set
71
Analog output select
0-3
1
75
Relay output select
0-10
2
77
External trip select
0-3
0
81
Factory settings
0-3
0
82
Start options
0-3
0
84
Display options
0-7
0
87
Security access code
0-999
0
Level 2 parameters are shaded.