19
2.1 Connections
AC Line Connection: Connect the AC line input to Terminals L1 (Line Fuse) and L2, of the
Barrier Terminal Block, as shown in Figure 2-2 and as described in Section 4.
The Voltage Select Switch position must match the AC line input voltage. See Section 6.
Note:
See Table 4-2 for AC Line and Armature Fuse selection. These items must be installed for the
control to operate.
Figure 2-2 AC Line, Armature, Field
*
, and Ground Connections
LINE
FIELD
ARMATURE
A-
A+
F-
F+
L1
L2
GND
-
Barrier
Terminal Block
DC Motor
Ground (Earth)
Ground (Earth)
Armature
Field˙ 115 or 208/230 Volts
AC Line Input
Note:
*F- and F+ are Field connections for Shunt Wound Motors only.
2.2
Ground Connection
Connect all ground wires (earth), of connections to the control, to the green ground screw on
the chassis, as shown in Figure 2-2.