Section 1
General Information
Appendix A-3
MN722
Table A-2 Power Output Parameter Block Values Level 1
Continued
Level 1 Blocks - Continued
Block Title
Parameter
P#
Adjustable Range
Factory
User
Setting
INPUT
OPERATING MODE
1401
KEYPAD
STANDARD RUN
15SPD
FAN PUMP 2 WIRE
FAN PUMP 3 WIRE
SERIAL
BIPOLAR
PROCESS MODE
KEYPAD
COMMAND SELECT
1402
POTENTIOMETER
+/-10 VOLTS
+/-5 VOLTS
4-20 mA
10V W/TORQ FF
EXB PULSE FOL
5VOLT EXB
10 VOLT EXB
4-20mA EXB
3-15 PSI EXB
TACHOMETER EXB
SERIAL
NONE
+/-10
VOLTS
ANA CMD INVERSE
1403
ON, OFF
OFF
ANA CMD OFFSET
1404
-20.0 TO +20.0%
(where
±
0.5V=
±
20%)
0.0 %
ANA 2 DEADBAND
1405
0-10.00 V
0.00 V
ANA 1 CUR LIMIT
1406
OFF, ON
OFF
OUTPUT
OPTO OUTPUT #1
1501
READY
ZERO SPEED
AT SPEED
OVERLOAD
READY
OPTO OUTPUT #2
1502
OVERLOAD
KEYPAD CONTROL
AT SET SPEED
FAULT
FOLLOWING ERR
ZERO
SPEED
OPTO OUTPUT #3
1503
FOLLOWING ERR
MOTR DIRECTION
DRIVE ON
CMD DIRECTION
AT POSITION
AT SPEED
OPTO OUTPUT #4
1504
AT POSITION
OVER TEMP WARN
PROCESS ERROR
DRIVE RUN
FAULT
ZERO SPD SET PT
1505
0-MAX Speed
200 RPM
AT SPEED BAND
1506
0-1000 RPM
100 RPM
SET SPEED
1507
0-MAX Speed
Rated Motor
Speed
Содержание 22H series
Страница 1: ...SERIES 22H Line Regen AC Flux Vector Control Installation Operating Manual 9 97 MN722 VECTOR DRIVE...
Страница 5: ...Section 1 General Information iv Table of Contents MN722...
Страница 105: ...Section 1 General Information 5 22 Troubleshooting MN722...
Страница 109: ...Section 1 General Information 6 4 Manual Tuning the Series 22H Control MN722...
Страница 137: ...Section 1 General Information A 8 Appendix A MN722...
Страница 138: ...Appendix B Appendix B 1 MN722...