Page 3
Circuit breaker selection and wiring requirements (Tab0):
Voltage
/Frequency
Amp.
Phase(s)
Breaker Size
(Amp./RCD)
Wire Size
220V~240V, 50/60Hz
10A
1
1x20A
3 x 4.0 mm
2
220V~240V, 50/60Hz
16 A
1
1x30A
3 x 6.0 mm
2
220V~240V, 50/60Hz
32A
1
1x60A
3 x 10.0 mm
2
220V~240V, 50/60Hz
42A
1
1x60A
3 x 10.0 mm
2
220V~240V, 50/60Hz
16A
2
2x30A
5 x 6.0 mm
2
380V, 50/60Hz
16A
3
3x30A
5 x 6.0 mm
2
380V, 50/60Hz
32A
3
3x60A
5 x 10.0 mm
2
REQUIREMENTS
Caution:
Your spa must be wired by a qualified and licensed electrician, and
according to the instructions below. Failure to do so will terminate all warranties.
(1) The spa must be hard wired to the power supply, with no plug-in connections,
extension cords, or sharing of service.
(2) The spa requires that you run 6mm
2
solid copper wire, depending on the size of
the residual current device (RCD) that you use. Please refer to Tab0 for details. Do