Preparation and Filling

Fill the spa to its correct operating level. Be sure to open all valves and jets in the plumbing system before fi lling to allow 
as much air as possible to escape from the plumbing and the control system during the fi lling process.

After turning the power on at the main power panel, the top-side panel will display a splash, or startup screen.

Priming Mode – M019*

After the initial start-up sequence, the control will enter Priming Mode and display a Priming Mode screen. Only pump icons 
appear on the priming mode screen. The system will automatically return to normal heating and fi ltering at the end of the 
priming mode, which lasts 4-5 minutes. During the priming mode, the heater is disabled to allow the priming process to be 
completed without the possibility of energizing the heater under low-fl ow or no-fl ow conditions. Nothing comes on auto-
matically, but the pump(s) can be energized by selecting the “Jet” buttons.  If the spa has a Circ Pump, it can be turned 
on and off by pressing the “Circ Pump” button during Priming Mode. In 
addition, if the spa has a Circ Pump, it can be activated by pressing the 
dedicated “Light” button during Priming Mode when using a TP800.

Manually exit Priming Mode by pressing the “Exit” Button.

Priming the Pumps

As soon as the Priming Mode screeen appears on the panel, select the 
“Jets 1” button once to start Pump 1 in low-speed and then again to 
switch to high-speed. Also, select the other pumps, to turn them on. 
The pumps should be running in high-speed to facilitate priming. If the 
pumps have not primed after 2 minutes, and water is not fl owing from 
the jets in the spa, do not allow the pumps to continue to run. Turn off 
the pumps and repeat the process. Note: Turning the power off and back on again will initiate a new pump priming session. 
Sometimes momentarily turning the pump off and on will help it to prime. Do not do this more than 5 times. If the pump(s) 
will not prime, shut off the power to the spa and call for service.

Important: A pump should not be allowed to run without priming for more than 2 minutes. Under NO circumstances should 
a pump be allowed to run without priming beyond the end of the 4-5 minute priming mode. Doing so may cause damage to 
the pump and cause the system to energize the heater and go into an overheat condition. 

Exiting Priming Mode

You can manually exit Priming Mode by navigating to the “Back” button on the Priming Mode Screen. Note that if you do 
not manually exit the priming mode as described above, the priming mode will be automatically terminated after 4-5 min-
utes. Be sure that the pump(s) have been primed by this time. 

Once the system has exited Priming Mode, the top-side panel will display the Main Screen, but the display will not show the 
temperature yet, as shown below. This is because the system requires approximately 1 minute of water fl owing through the 
heater to determine the water temperature and display it.

Fill it up!

Priming Mode

Exit

Jets 1

Jets 2

Jets 3

Circ

– – –°F

– – –°C

*M019 is a Message Code. See Fault Log on Page 13. 

Содержание TP800 series

Страница 1: ... both foreign and domestic applied for and pending All material copyright of Balboa Water Group TP800 and TP900 Series Control Panels Balboa Water Group Colossus Series User Interface and Programming Reference System Model BP2500 2600 Software Version 5 0 and later Panel Model TP900 Series TP800 Series Software Version 2 0 or later 1 9 or later Set 104 F 8 32 PM Ozone Filter 1 Spa Shortcuts Settin...

Страница 2: ... accessed from this screen The actual water temperature can be seen in large text and the desired or Set Temperature can be selected and adjusted Time of day Ozone operation and Filter Operation status is available along with other messages and alerts High Temperature Range vs Low Temperature Range is indicated in the upper right corner The Jets Icon in the center will spin on a TP900 if any pump ...

Страница 3: ...Set Temperature Press the Left Arrow button to change the Set Temperature number to white The Set Temperature can then be adjusted with the up and down buttons Pressing the Select button or the Right Arrow button will save the new set temperature On the right side of the screen the menu selections can be selected with the Up and Down Buttons Use the Select Button to choose an item Selecting one of...

Страница 4: ...der the icon changes to white Once a device is selected it can be controlled using the center Select Button Some devices like pumps may have more than one ON state so the icon will change to reflect the state that the equipment is in Below are some examples of 2 speed Pump indicators Jets High Jets Low Jets Off If the Spa has a Circ Pump a Circ Pump Icon will appear to indicate its activity but ou...

Страница 5: ...ice while on the Shortcuts Screen if the device is one of the 4 functions available Settings Back Temp Range Heat Mode Time of Day Filter Cycles Light Cycle Invert Panel Lock High Ready Normal Press and Hold If an Up or Down button is pressed and held when an item in a Menu List is highlighted the list can be scrolled quickly from top to bottom The scroll bar on the right side of the screen indica...

Страница 6: ...nt temperature until the heater pump has been running for a minute or two While Pump 1 High can be turned on and off Pump 1 Low will run until set temperature is reached or 1 hour has passed Circulation Mode See Page 8 under Pumps for other circulation modes If the spa is configured for 24HR circulation the heater pump generally runs continuously Since the heater pump is always running the spa wil...

Страница 7: ...ton Priming the Pumps As soon as the Priming Mode screeen appears on the panel select the Jets 1 button once to start Pump 1 in low speed and then again to switch to high speed Also select the other pumps to turn them on The pumps should be running in high speed to facilitate priming If the pumps have not primed after 2 minutes and water is not flowing from the jets in the spa do not allow the pum...

Страница 8: ...eze conditions or when another pump is on The specific Circulation Mode that is used has been determined by the Manufacturer and cannot be changed in the field Other device options may be available like Blower Light Mist etc Filtration and Ozone On non circ systems Pump 1 low and the ozone generator will run during filtration On circ systems the ozone will gener ally run with the circ pump but can...

Страница 9: ...f Day screen simply navigate right and left to select the Hour Minutes AM PM and 12 24 Hour segments Use the Up and Down Buttons to make changes Saving Settings The Time of Day screen is a simple editable screen that illustrates a feature of the control that applies to all other editable screens as well When changes are made the icon to go Back changes to Save and a new icon for Cancel appears und...

Страница 10: ...Cycle 1 by navigating to the right It is possible to overlap Filter Cycle 1 and Filter Cycle 2 which will shorten overall filtration by the overlap amount Circulation Pump Modes Some spas may be manufactured with Circ Pump settings that allow programming filtration cycle duration Some circ Modes are pre programmed to operate 24 hours a day and are not programmable Refer to the spa manufacturer s d...

Страница 11: ... default The settings can be edited the same way that Filter Cycles are edited see page 10 Specific Buttons for Specific Devices If the panel has dedicated function buttons TP800 or the spa has an Auxiliary Panel s installed pressing those buttons will activate the device indicated for that button These dedicated buttons will operate just like the Spa Screen buttons see page 4 and the equipment wi...

Страница 12: ...r both Panel Lock and Settings Lock The control can be restricted to prevent unwanted use or temperature adjustments Locking the Panel prevents the controller from being used but all automatic functions are still active Locking the Settings allows Jets and other features to be used but the Set Temperature and other programmed settings cannot be adjusted Settings Lock allows access to a reduced sel...

Страница 13: ...Mode Utilities The Utilities Menu contains the following A B Temps When this is set to On the temperature display will alternate to display temperature from Sensor A and Sensor B in the heater Demo Mode Demo Mode is not always enabled so it may not appear This is designed to operate several devices in a sequence in order to demonstrate the various features of a particular hot tub Fault Log The Fau...

Страница 14: ...eminders Turn the reminder messages like Clean Filter On or Off Cleanup Cleanup Cycle Duration is not always enabled so it may not appear When it is available set the length of time Pump 1 will run after each use 0 4 hours are available Dolphin II and Dolphin III Applies to RF Dolphin only When set to 0 no addressing is used Use this setting for a Dolphin II or Dolphin III which is factory set for...

Страница 15: ...stem Model Displays the Model Number of the System Current Setup Displays the currently selected Configuration Setup Number Configuration Signature Displays the checksum for the system configuration file Heater Voltage Feature not used on CE rated systems Displays the operating voltage configured for the heater Heater Wattage as Configured in Software CE Systems Only Displays a heater kilowatt rat...

Страница 16: ...ut off until a service person can correct the problem Forcing the GFCI Trip Test North America Only The installer can cause the GFCI Trip Test to occur sooner by initiating it using the above menu The GFCI should trip within several seconds and the spa should shut down If it does not shut down the power and manually verify that a GFCI breaker is installed and that the circuit and spa are wired cor...

Страница 17: ...message can be selected by navigating to it at pressing the Select button The water is too hot M029 The system has detected a spa water temp of 110 F 43 3 C or more and spa functions are disabled System will auto reset when the spa water temp is below 108 F 42 2 C Check for extended pump operation or high ambient temp This message can be reset from the topside panel Possible freezing condition A p...

Страница 18: ...in heater start up The heater may be dry M028 Possible dry heater or not enough water in the heater to start it The spa is shut down for 15 min Press any button to reset the heater start up See Flow Related Checks below The heater is dry M027 There is not enough water in the heater to start it The spa is shut down After the problem has been resolved you must clear the message to restart heater sta...

Страница 19: ...or 3 F Call for Service Sensors are out of sync Call for service M026 The temperature sensors ARE out of sync The fault above has been established for at least 1 hour Call for Service Sensor A Fault Senor B Fault Sensor A M031 Sensor B M032 A temperature sensor or sensor circuit has failed Call for Service Communications error The control panel is not receiving communication from the System Call f...

Страница 20: ... organization The GFCI test failed System Could Not Test the GFCI M036 North America Only May indicate an unsafe installation Contact your dealer or service organization Hot fault M035 A Pump Appears to have been Stuck ON when spa was last powered POWER DOWN THE SPA DO NOT ENTER THE WATER Contact your dealer or service organization A pump may be stuck on M034 Water may be overheated POWER DOWN THE...

Страница 21: ...I or RCD associated with the hot tub installation A GFCI or RCD will have a TEST and RESET button on it that allows a user to verify proper function General maintenance helps Reminder Messages can be suppressed by using the Preferences Menu See Page 14 Reminder Messages can be chosen individually by the Manufacturer They may be disabled entirely or there may be a limited number of reminders on a s...

Страница 22: ... instruction manual Adequate drainage must be provided if the equipment is to be installed in a pit For use only within an enclosure rated CSA Enclosure 3 Connect only to a circuit protected by a Class A ground fault circuit interrupter or residual current device To ensure continued protection against shock hazard use only identical replacement parts when servicing Install a suitably rated suction...

Отзывы: