Masoneilan 4700P/E & 4800P/E Positioners Manual | 35
© 2021 Baker Hughes Company. All rights reserved.
Lever S/A Orientation
See “Field Mounting and Complete Calibration, Rotary Actuators” on page 40 and “Field
Mounting and Complete Calibration Reciprocating Valves using 87/88 Actuators” on page 43).
The relative position of the lever S/A (3) for a selected cam lobe must be correct. The lever S/A
can be mounted with its pivot post to the left or right of the cam center.
Changing Lever S/A Orientation
See “Field Mounting and Complete Calibration, Rotary Actuators” on page 54 and “Field
Mounting and Complete Calibration Reciprocating Valves using 87/88 Actuators” on page 43).
If lever S/A (3) must be changed, remove screw (28), lockwasher (51) and washer (27), and
cam (26) from cam shaft. Remove retaining ring (17) and flat washer (16). Remove lever S/A
(3) from pivot post. Lift and rotate lever S/A (3) on spring end 180° to desired position. (Do not
rotate spring end; socket head screw on spring must face outward.) Replace flat washer (16)
and retaining ring (17) on pivot post.
Содержание Masoneilan 4700P
Страница 16: ...2021 Baker Hughes Company All rights reserved 16 Baker Hughes Figure 5 87 88 Actuator...
Страница 30: ...2021 Baker Hughes Company All rights reserved 30 Baker Hughes Figure 12 FM Installation...
Страница 32: ...2021 Baker Hughes Company All rights reserved 32 Baker Hughes Figure 14 ATEX Installation...
Страница 63: ...Masoneilan 4700P E 4800P E Positioners Manual 63 2021 Baker Hughes Company All rights reserved NOTES...
Страница 64: ...2021 Baker Hughes Company All rights reserved 64 Baker Hughes NOTES...
Страница 65: ...Masoneilan 4700P E 4800P E Positioners Manual 65 2021 Baker Hughes Company All rights reserved NOTES...